文献速递神经肿瘤

脑神经肿瘤学中5-氨基乙酰丙酸的假阳性:并非所有荧光都是肿瘤——基于病例的更新与文献综述

5-Aminolevulinic Acid False Positives in Cerebral Neuro-Oncology: Not All That Is Fluorescent Is Tumor. A Case-Based Update and Literature Review.
PubMed 文献 · World Neurosurg · 2020-02-10

该综述通过PubMed检索相关文献,系统梳理了可模拟高级别胶质瘤并导致术中误诊的非肿瘤性及其他代谢活跃病变,并报告了1例放射性坏死出现强烈5-ALA荧光的本院病例。文献结果按肿瘤学背景(9篇文献和1例本院病例)与非肿瘤学背景(5篇文献)两类归纳。结论指出5-ALA诱导的荧光不限于胶质瘤,在非胶质瘤和非肿瘤性病变中也可出现,因此在复发和不典型病例中必须批判性解读术中荧光。

要点

  • 5-ALA荧光并非胶质瘤特异,非胶质瘤及非肿瘤性病变也可出现荧光。
  • 文献按肿瘤学背景(9篇文献和1例本院病例)与非肿瘤学背景(5篇文献)归类。
  • 在复发和不典型病例中,对术中5-ALA荧光须批判性解读。

核心结论

  • 5-ALA诱导的荧光不限于胶质瘤,在非胶质瘤和非肿瘤性病变中也可出现,因此对复发和不典型病例的术中荧光须批判性解读。

研究设计与样本

  • 通过PubMed检索相关文献,专门调查所有可模拟高级别胶质瘤并导致术中误诊的病变,包括非肿瘤性及其他代谢活跃病变;另报告1例放射性坏死出现强烈5-ALA荧光的本院病例。

主要发现

  • 文献结果按应用领域分为2类:肿瘤学背景(9篇文献和1例本院病例)与非肿瘤学背景(5篇文献)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: One of the most valuable innovations in high-grade glioma surgery is 5-aminolevulinic acid (5-ALA). Fluorescence is a specific and sensitive indicator of metabolically active tumor tissue. In the published literature, the main focus has been placed on false-negative cases, with only a few articles addressing false positivity. The aim of the article was to highlight settings in which 5-ALA fluorescence does not necessarily mean tumor and to point out conditions in which intraoperative 5-ALA fluorescence has to be critically interpreted. METHODS: Using PubMed, a review of pertinent literature was done to specifically investigate all conditions, including non-neoplastic and other metabolically active lesions, that can mimic high-grade gliomas and cause a misleading intraoperative diagnosis. In addition, an institutional case characterized by strong 5-ALA fluorescence in radionecrosis is presented. RESULTS: Literature results were grouped in 2 main categories according to the field of application: oncologic setting (9 articles and 1 institutional case) and nononcologic settings (5 articles). CONCLUSIONS: As reported, 5-ALA-induced fluorescence is not limited to glioma but is also evident in nonglioma and non-neoplastic conditions. Critical interpretation of intraoperative fluorescence is therefore mandatory in recurrences and in atypical cases that might hinder alternative diagnoses.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. La Rocca G, Sabatino G, Menna G, et al. 5-Aminolevulinic Acid False Positives in Cerebral Neuro-Oncology: Not All That Is Fluorescent Is Tumor. A Case-Based Update and Literature Review. World Neurosurg. 2020. PMID: 32058110. doi:10.1016/j.wneu.2020.01.238

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。