术中3-T磁共振波谱检测胶质瘤增殖性残留
研究纳入15例新诊断胶质瘤患者,在术中磁共振成像辅助手术中同步行单 voxel 3-T 术中磁共振波谱(iMRS),于切除缘T2高信号或强化病灶放置20个感兴趣区(VOI)。结果显示Cho/NAA比值与MIB-1指数呈显著正相关(r=0.46,P=0.04),MIB-1阳性VOI的Cho水平(P=0.003)和Cho/NAA比值(P=0.002)显著高于MIB-1阴性VOI;Cho>1.074 mM诊断MIB-1阳性残留的灵敏度86%、特异度100%,Cho/NAA>0.48的灵敏度79%、特异度100%。
要点
- 术中3-T iMRS可用于检测胶质瘤切除缘增殖性残留。
- MIB-1阳性VOI的Cho水平和Cho/NAA比值显著高于MIB-1阴性VOI。
- Cho>1.074 mM和Cho/NAA>0.48对MIB-1阳性残留诊断准确率高。
核心结论
- 3-T iMRS可通过Cho水平和Cho/NAA比值检测胶质瘤切除缘的增殖性残留。
- 作者认为术中磁共振成像辅助手术联合iMRS在胶质瘤中可行。
研究设计与样本
- 研究纳入15例新诊断胶质瘤患者,在术中磁共振成像辅助手术中同步行单 voxel 3-T iMRS。
- 于切除缘T2高信号或强化病灶放置感兴趣区(VOI),共对20个VOI行iMRS。
- 分析MIB-1标记指数与iMRS测得的N-乙酰-L-天冬氨酸(NAA)、胆碱(Cho)及Cho/NAA比值的相关性。
主要发现
- 20个VOI中14个(70%)确认为MIB-1阳性。
- Cho/NAA比值与MIB-1指数呈显著正相关(r=0.46,P=0.04)。
- MIB-1阳性VOI的Cho水平显著高于MIB-1阴性VOI(P=0.003)。
- MIB-1阳性VOI的Cho/NAA比值显著高于MIB-1阴性VOI(P=0.002)。
- Cho>1.074 mM诊断MIB-1阳性残留的灵敏度86%、特异度100%;Cho/NAA>0.48的灵敏度79%、特异度100%。
关键数值与推荐
- Cho水平>1.074 mM诊断MIB-1阳性残留:灵敏度86%,特异度100%。
- Cho/NAA比值>0.48诊断MIB-1阳性残留:灵敏度79%,特异度100%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Few studies have examined the usefulness of intraoperative magnetic resonance spectroscopy (iMRS) for identifying abnormal signals at the resection margin during glioma surgery. The aim of this study was to assess the value of iMRS for detecting proliferative remnants of glioma at the resection margin. METHODS: Fifteen patients with newly diagnosed glioma underwent single-voxel 3-T iMRS concurrently with intraoperative magnetic resonance imaging-assisted surgery. Volumes of interest (VOIs) were placed at T2-hyperintense or contrast-enhancing lesions at the resection margin. In addition to technical verification, the correlation between the MIB-1 labeling index (a pathologic feature) and metabolites measured using iMRS (N-acetyl-L-aspartate [NAA], choline [Cho], and Cho/NAA ratio) was analyzed. RESULTS: iMRS was performed for 20 VOIs in 15 patients. Fourteen (70%) of these VOIs were confirmed to be MIB-1-positive. There was a significant positive correlation between the Cho/NAA ratio and MIB-1 index (r = 0.46, P = 0.04). Cho level (P = 0.003) and Cho/NAA ratio (P = 0.002) were significantly higher in VOIs that were MIB-1-positive than in those that were MIB-1-negative. Detection of a Cho level >1.074 mM and a Cho/NAA ratio >0.48 using iMRS resulted in high diagnostic accuracy for MIB-1-positive remnants (Cho level: sensitivity 86%, specificity 100%; Cho/NAA ratio: sensitivity 79%, specificity 100%). CONCLUSIONS: This study provides evidence that 3-T iMRS can detect proliferative remnants of glioma at the resection margin using the Cho level and Cho/NAA ratio, suggesting that intraoperative magnetic resonance imaging-assisted surgery with iMRS would be practicable in glioma.
引用
- Fujita Y, Kohta M, Sasayama T, et al. Intraoperative 3-T Magnetic Resonance Spectroscopy for Detection of Proliferative Remnants of Glioma. World Neurosurg. 2020. PMID: 32035198. doi:10.1016/j.wneu.2020.01.217
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。