将患者流入条件变异性纳入动脉瘤破裂评估的统计模型
研究基于1820个动脉瘤的影像数据,用9种不同流入速率进行稳态计算流体动力学模拟,计算17个血流动力学参数;在1571个动脉瘤中训练两种破裂预测统计模型(模型A定义血流动力学响应变量,模型B按患者重复随机选择流动条件),并在剩余249例中评估。两模型曲线下面积分别为0.8182和0.8174±0.0045,表明可将患者间及患者内血流变异纳入动脉瘤破裂预测模型。
要点
- 不同流入条件下所有血流动力学参数均有显著差异(p < 0.001)。
- 模型A的受试者工作特征曲线下面积为0.8182。
- 模型B的受试者工作特征曲线下面积为0.8174±0.0045。
核心结论
- 患者间及患者内血流变异对计算血流动力学的影响可纳入多变量动脉瘤破裂预测模型,并获得良好预测性能。
研究设计与样本
- 使用1820个动脉瘤的影像数据进行患者特异性稳态计算流体动力学模拟,每例采用9种不同流入速率以捕捉患者间及患者内血流变异。
- 基于计算流场计算17个血流动力学参数,并比较不同流动条件下的差异。
- 在1571个动脉瘤中训练动脉瘤破裂统计模型,纳入通过定义血流动力学「响应变量」(模型A)或按患者重复随机选择流动条件(模型B)以捕捉血流变异的血流动力学参数,以及形态学和患者特异性变量。
- 在剩余249例中评估两种模型。
主要发现
- 所有血流动力学参数在不同流动条件下均有显著差异(p < 0.001)。
- 不依赖流动的「响应」模型A的受试者工作特征曲线下面积为0.8182。
- 依赖流动的模型B的受试者工作特征曲线下面积为0.8174±0.0045。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Hemodynamic patterns have been associated with cerebral aneurysm instability. For patient-specific computational fluid dynamics (CFD) simulations, the inflow rates of a patient are typically not known. The aim of this study was to analyze the influence of inter- and intra-patient variations of cerebral blood flow on the computed hemodynamics through CFD simulations and to incorporate these variations into statistical models for aneurysm rupture prediction. METHODS: Image data of 1820 aneurysms were used for patient-specific steady CFD simulations with nine different inflow rates per case, capturing inter- and intra-patient flow variations. Based on the computed flow fields, 17 hemodynamic parameters were calculated and compared for the different flow conditions. Next, statistical models for aneurysm rupture were trained in 1571 of the aneurysms including hemodynamic parameters capturing the flow variations either by defining hemodynamic "response variables" (model A) or repeatedly randomly selecting flow conditions by patients (model B) as well as morphological and patient-specific variables. Both models were evaluated in the remaining 249 cases. RESULTS: All hemodynamic parameters were significantly different for the varying flow conditions (p < 0.001). Both the flow-independent "response" model A and the flow-dependent model B performed well with areas under the receiver operating characteristic curve of 0.8182 and 0.8174 ± 0.0045, respectively. CONCLUSIONS: The influence of inter- and intra-patient flow variations on computed hemodynamics can be taken into account in multivariate aneurysm rupture prediction models achieving a good predictive performance. Such models can be applied to CFD data independent of the specific inflow boundary conditions.
引用
- Detmer FJ, Mut F, Slawski M, et al. Incorporating variability of patient inflow conditions into statistical models for aneurysm rupture assessment. Acta Neurochir (Wien). 2020. PMID: 32008209. doi:10.1007/s00701-020-04234-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。