脑室内灌注试验诊断特发性正常压力脑积水的时机
本研究纳入10例拟行脑室内灌注试验的特发性正常压力脑积水(iNPH)疑似患者,在脑室外引流(EVD)置入后1小时与24小时两个时间点测量基线颅内压(ICP)、平台ICP并计算流出阻力(Rout)进行自身对照。结果显示Rout、基线ICP与平台ICP在两个时间点间均无统计学显著差异,作者据此提出灌注试验可在术后早期进行。
要点
- EVD置入后1小时与24小时的Rout、基线ICP、平台ICP均无统计学显著差异。
- 7例配对灌注试验中,有2例患者1小时与24小时的Rout值一致性差。
- 作者提出灌注试验可在术后早期进行,以缩短EVD留置时间和住院时间。
核心结论
- 总体上,EVD置入后1小时与24小时之间Rout估计值无显著变化,作者据此提出灌注试验可在术后早期进行,以减少EVD留置时间和住院时长。
研究设计与样本
- 单中心自身对照研究,纳入10例拟行脑室内灌注试验的iNPH疑似患者,在EVD置入后1小时与24小时两个时间点行恒速脑室内灌注试验并计算Rout。
- 本研究中心(our department)的常规做法是EVD置入到灌注试验间隔24小时,原因是担心手术操作可能影响术后即刻的试验结果。
主要发现
- 8例患者完成两次灌注试验;18次灌注试验中1次无法确定ICP平台期而被排除,最终7对配对灌注试验。
- Rout中位数在EVD置入后1小时为12.9 mmHg/ml/min(范围7.0-22.0),24小时后为11.3 mmHg/ml/min(范围7.8-18.1)。
- EVD置入后1小时与24小时相比,Rout(P=0.83)、基线ICP(P=0.70)、平台ICP(P=0.81)均无统计学显著差异。
- 7例配对灌注试验患者中有2例,1小时与24小时的Rout值一致性差。
临床怎么用
- 作者提出灌注试验可在术后早期进行,以缩短EVD留置时间和住院时长。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Infusion tests, which measure resistance to outflow (Rout), are used in selecting patients suspected for idiopathic normal pressure hydrocephalus (iNPH) for shunt surgery. Infusion tests can be performed through an external ventricular drain (EVD). A 24-hour time gap from EVD insertion to an infusion test is a routine practice at our department due to concerns that the surgical procedure might influence the test results in the immediate postoperative period. The objective of the study was to investigate if timing of an intraventricular infusion test influences the results of the test in patients suspected for iNPH. METHODS: Ten patients scheduled for an intraventricular infusion test were included. Measurements of baseline intracranial pressure (ICP) and plateau ICP were obtained during constant rate intraventricular infusion test performed at two time points (1 and 24 h after EVD insertion) and Rout was calculated from these measures and compared within patients. RESULTS: Eight patients completed both infusion tests. In one of the 18 infusion tests performed, it was not possible to define an ICP plateau and this infusion test was excluded, leaving 7 paired infusion tests. Median Rout was 12.9 mmHg/ml/min (range 7.0-22.0) 1 h after EVD insertion and 11.3 mmHg/ml/min (range 7.8-18.1) after 24 h. Overall, there were no statistically significant differences in Rout (P = 0.83), baseline ICP (P = 0.70), or plateau ICP (P = 0.81) between the recordings performed 1 h and 24 h after EVD insertion. For two of the seven patients with paired infusion tests, there was poor agreement between Rout values at 1 and 24 h. CONCLUSION: Overall, Rout estimates do not change significantly between 1 and 24 h after EVD insertion. We therefore propose that infusion tests can be performed shortly after surgery to reduce the period of indwelling EVD and duration of hospitalization.
引用
- Andreasen TH, Lilja-Cyron A, Holst AV, et al. Timing of intraventricular infusion test for diagnosing idiopathic normal pressure hydrocephalus. Acta Neurochir (Wien). 2020. PMID: 31912355. doi:10.1007/s00701-019-04168-w