文献速递脑血管病外科

新型网状临时桥接装置(Cascade)辅助颅内动脉瘤血管内弹簧圈栓塞的早期经验

Early experience with a novel net temporary bridging device (Cascade) to assist endovascular coil embolization of intracranial aneurysms.
PubMed 文献 · J Neurosurg · 2020-01-24

本研究评估新型非完全闭塞性网状辅助重塑技术中Cascade网状装置临时桥接颅内动脉瘤的有效性和安全性。2018年7月至2019年5月欧洲4中心15例患者接受弹簧圈栓塞,术后即刻MRRC I型11例(73.3%)、II型4例(26.7%),7例随访显示动脉瘤闭塞稳定,无血栓栓塞并发症,仅1例因弹簧圈压缩MRRC评分从I升至II。初步经验显示该技术可能安全有效。

要点

  • 15例颅内动脉瘤患者使用Cascade网状装置辅助弹簧圈栓塞,10例未破裂、5例破裂伴急性蛛网膜下腔出血。
  • 术后即刻MRRC I型(完全闭塞)11例(73.3%),II型(残留瘤颈)4例(26.7%)。
  • 7例随访显示动脉瘤闭塞稳定,无血栓栓塞并发症,仅1例MRRC从I升至II。

核心结论

  • 初步经验显示,使用新型非完全闭塞性网状辅助重塑技术及Cascade网状装置进行颅内动脉瘤血管内弹簧圈栓塞可能安全有效。

研究设计与样本

  • 2018年7月至2019年5月在欧洲4个中心开展的研究,纳入接受Cascade网状装置辅助弹簧圈栓塞的患者。
  • 共纳入15例患者,平均年龄58±13岁,女性11/15(73.3%)。
  • 10例为未破裂动脉瘤,5例为破裂动脉瘤伴急性蛛网膜下腔出血。
  • 平均动脉瘤顶长度6.27±2.33 mm,平均瘤颈宽度3.64±1.19 mm。
  • 分析术后即刻及6个月随访的血管造影(改良Raymond-Roy分类[MRRC])和临床结局数据。

主要发现

  • 术后即刻MRRC I型(完全闭塞)11例(73.3%),MRRC II型(残留瘤颈)4例(26.7%)。
  • 随访检查在7/15例患者中进行,显示动脉瘤闭塞稳定,无血栓栓塞并发症。
  • 仅1例患者因弹簧圈压缩导致MRRC评分从I型升至II型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The goal of this study was to evaluate the effectiveness and safety of a new noncompletely occlusive net-assisted remodeling technique in which the Cascade net device is used for temporary bridging of intracranial aneurysms. METHODS: Between July 2018 and May 2019, patients underwent coil embolization with the Cascade net device within 4 centers in Europe. Analysis of angiographic (modified Raymond-Roy classification [MRRC]) and clinical outcomes data was conducted immediately following treatment and at the 6-month follow-up. RESULTS: Fifteen patients were included in the study (mean age 58 ± 13 years, 11/15 [73.3%] female). Ten patients had unruptured aneurysms, and 5 presented with ruptured aneurysms with acute subarachnoid hemorrhage. The mean aneurysm dome length was 6.27 ± 2.33 mm and the mean neck width was 3.64 ± 1.19 mm. Immediately postprocedure, MRRC type I (complete obliteration) was achieved in 11 patients (73.3%), whereas a type II (residual neck) was achieved in 4 patients (26.7%). Follow-up examination was performed in 7/15 patients and showed stabilization of aneurysm closure with no thromboembolic complications and only 1 patient with an increased MRRC score (from I to II) due to coil compression. CONCLUSIONS: Initial experience shows that the use of a new noncompletely occlusive net-assisted remodeling technique with the Cascade net device may be safe and effective for endovascular coil embolization of intracranial aneurysms.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Tomasello A, Hernandez D, Gramegna LL, et al. Early experience with a novel net temporary bridging device (Cascade) to assist endovascular coil embolization of intracranial aneurysms. J Neurosurg. 2020. PMID: 31978881. doi:10.3171/2019.11.JNS192477

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。