脊髓造影后脑室腹腔分流管梗阻一例独特病例报告及其治疗
本文报告一例23岁女性Ⅰ型神经纤维瘤病、梗阻性脑积水、脑室腹腔分流术后患者,在脊髓造影中使用碘海醇(Omnipaque)后出现分流管梗阻和嗜睡,CT显示脑室明显扩大;经分流管穿刺和泵压方案后梗阻及脑积水缓解,恢复至基线。作者建议医生考虑诊断性脊髓造影后分流梗阻可能,对可调压分流管患者应谨慎并密切观察。
要点
- 脊髓造影后使用碘海醇(Omnipaque)可能导致脑脊液黏度增加,进而引起分流阀梗阻。
- 患者表现为嗜睡,头颅CT显示脑室明显扩大。
- 分流管穿刺和泵压方案可有效缓解机械性梗阻并恢复分流管通畅。
核心结论
- 脊髓造影后脑室腹腔分流管梗阻为近期病例,既往报告病例已过去数十年。
- 分流管泵压方案可能是一种非手术、有效的机械性梗阻处理方法,可恢复分流系统流量和通畅。
- 作者鼓励医生考虑诊断性脊髓造影后分流梗阻的可能性。
- 对使用可调压脑室腹腔分流管的患者进行脊髓造影时,应考虑谨慎和密切观察。
研究设计与样本
- 病例报告:一例23岁女性患者,有Ⅰ型神经纤维瘤病、梗阻性脑积水、颈椎前路椎间盘切除融合术和脑室腹腔分流置入术病史。
主要发现
- 患者在接受碘海醇(Omnipaque)脊髓造影后出现嗜睡,头颅CT显示脑室明显扩大,诊断为脑室腹腔分流管梗阻。
- 经分流管穿刺和泵压方案后,梗阻和脑积水缓解,患者恢复至神经系统基线状态。
临床怎么用
- 作者建议医生考虑诊断性脊髓造影后分流梗阻的可能性。
- 作者建议对使用可调压脑室腹腔分流管的患者进行脊髓造影时谨慎并密切观察。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Myelography, frequently supplanted by noninvasive, efficient magnetic resonance imaging, remains a useful technique when evaluating the spinal canal in nerve root avulsion, radiation therapy treatment planning, cerebrospinal fluid (CSF) loculation, and CSF leak. Myelography is achieved through a lumbar puncture and instillation of nonionic, water-soluble intrathecal iohexol (Omnipaque, GE Healthcare, Marlborough, Massachusetts, USA) contrast. The aim of the study was to highlight a possible complication of obstruction of a shunt valve due to an increased viscosity of the CSF after intrathecal Omnipaque contrast administration during myelography. CASE DESCRIPTION: The authors report a case of myelography that resulted in obstruction of a ventriculoperitoneal (VP) shunt. A 23-year-old female with significant medical history of neurofibromatosis type I, obstructive hydrocephalus, anterior cervical diskectomy and fusion, and VP shunt placement underwent diagnostic computed tomography after myelography with Omnipaque contrast to assess possible CSF loculation and cord impingement from her cervical instrumentation. The patient experienced somnolence after myelography from obstruction of the VP shunt, with marked ventriculomegaly demonstrated by computed tomography of the head. A shunt tap and shunt pumping regimen resulted in resolution of the obstruction and hydrocephalus, with return to neurologic baseline. CONCLUSIONS: This is a recent case of VP shunt obstruction after myelography, of which previous cases reported are decades old. A shunt pumping regimen may be a nonoperative, effective mean for similar mechanical obstructions of VP shunts for restoration of flow and patency of the shunt system in these patients. We encourage physicians to consider the possibility of shunt obstruction after diagnostic myelography. Caution and close observation should be considered in patients undergoing myelography with a programmable VP shunt.
引用
- Silva NA, Goldstein IM. Obstruction of Ventriculoperitoneal Shunt After Myelography-Report of a Unique Case and Its Treatment. World Neurosurg. 2019. PMID: 31756508. doi:10.1016/j.wneu.2019.11.067