文献速递脊柱脊髓外科

胸腰段双椎体柱切除中脊髓短缩的安全限度:山羊实验研究

Safe Limit of Shortening of the Spinal Cord in Thoracolumbar Bivertebral Column Resections: An Experimental Study in Goats.
PubMed 文献 · World Neurosurg · 2019-10-31

在山羊模型中研究胸腰段双椎体柱切除(T13和L1)时脊髓短缩的安全限度,通过体感诱发电位(SSEP)监测确定安全短缩距离为35.2±2.6 mm,约等于平均截骨椎体高度的127.6%和初始截骨间隙高度的57.1%,且与T13高度、L1高度、平均高度及初始截骨间隙高度相关。

要点

  • 双椎体柱切除脊髓短缩安全限度为35.2±2.6 mm,约等于平均截骨椎体高度的127.6%。
  • 安全限度约等于初始截骨间隙高度的57.1%,且与截骨椎体高度及初始间隙高度相关。
  • 双椎体柱切除的安全短缩距离长于单椎体柱切除,增加切除椎体数可能防止过度短缩致脊髓损伤。

核心结论

  • 双椎体柱切除的安全短缩距离约等于平均截骨椎体高度的127.6%和初始截骨间隙高度的57.1%,且相关性良好;该安全限度长于单椎体柱切除,增加切除椎体数可能防止过度短缩致脊髓损伤。

研究设计与样本

  • 实验研究,选取10只健康山羊,术前摄X线片测量T13、L1及初始截骨段(T12下终板至L2上终板距离)高度,在SSEP监测下完成胸腰段双椎体柱切除(T13和L1)。

主要发现

  • 脊髓短缩安全限度为35.2±2.6 mm,约等于平均截骨椎体高度的127.6%和初始截骨间隙高度的57.1%。
  • Pearson相关检验显示安全短缩限度与T13高度、L1高度、T13和L1平均高度及初始截骨间隙高度相关。
  • 双椎体柱切除的安全短缩距离长于单椎体柱切除。

关键数值与推荐

  • SSEP波幅较基线下降50%和/或峰潜伏期较基线延迟10%设为阳性结果,提示脊髓损伤。
  • 术后第2天采用Tarlov评分评估后肢功能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To clarify the safe limit of shortening of the spinal cord in thoracolumbar bivertebral column resection in a goat model. METHODS: Ten healthy goats were selected for the experiment. Radiographs were taken before surgery to measure the height of T13, L1, and the initial osteotomy segment (distance from the lower end plate of T12 to the upper end plate of L2). A procedure of thoracolumbar bivertebral column resection (T13 and L1) was completed under the monitoring of somatosensory evoked potential (SSEP) monitoring. The SSEP measured after vertebral resection was set as the baseline. SSEPs decreased by 50% from the baseline amplitude and/or delayed by 10% relative to the baseline peak latency were set as positive results, indicating spinal cord injury. The initial height of the osteotomy gap was measured first and the spinal column was gradually shortened until the SSEP monitoring did not show a positive result. Then the height of the osteotomy gap was recorded again. The safe limit of shortening was measured and recorded when any morphologic change of the spinal cord was observed. Hindlimb function was evaluated by the Tarlov scores on day 2 postoperatively. RESULTS: The safe limit of shortening of the spinal cord in thoracolumbar bivertebral columns resection was 35.2 ± 2.6 mm, which was roughly equal to 127.6% of the mean osteotomy vertebral height and 57.1% of the initial osteotomy gap height. Pearson correlation test showed that the safe limit of shortening of the spinal cord was correlated with the height of T13, the height of L1, the mean height of T13 and L1, and the height of the initial osteotomy gap. CONCLUSIONS: The safe limit of shortening distance of the bivertebral column resection was roughly equal to 127.6% of the mean osteotomy vertebral height and 57.1% of the initial osteotomy gap height with good correlation. Moreover, the safe limit of shortening distance of the bivertebral column resection was longer than that in single vertebral column resection. Increasing the number of vertebrae resected may prevent spinal cord injury because of excessive shortening.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Yang H, Wang B, Zou X, et al. Safe Limit of Shortening of the Spinal Cord in Thoracolumbar Bivertebral Column Resections: An Experimental Study in Goats. World Neurosurg. 2019. PMID: 31678449. doi:10.1016/j.wneu.2019.10.140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。