图像引导经颅多普勒超声监测幕下动脉出血后血管痉挛的可行性研究

Image-Guided Transcranial Doppler Ultrasound for Monitoring Posthemorrhagic Vasospasms of Infratentorial Arteries: A Feasibility Study.
PubMed 文献 · World Neurosurg · 2019-11-01

该可行性研究纳入10例蛛网膜下腔出血患者,每例接受5次序列图像引导经颅多普勒超声检查,评估幕下及幕上动脉监测血管痉挛的空间精确性与可重复性。结果显示预规划靶点与最佳多普勒信号间平均距离为4.8±2.1 mm(首次检查),空间精确性随血管靶点深度增加而下降,序列检查间空间精确性无显著变化。

要点

  • 图像引导经颅多普勒超声在幕上和幕下动脉均可行,可检测所有预定义的血管节段。
  • 首次检查中预规划靶点与最佳多普勒信号的平均距离为4.8±2.1 mm,提示高空间精确性。
  • 空间精确性随血管靶点深度增加而下降,序列检查间无显著变化提示高可重复性。

核心结论

  • 图像引导经颅多普勒超声对幕上和幕下动脉均可行,显示出高空间精确性和可重复性,为未来蛛网膜下腔出血后血管痉挛筛查的临床研究提供了基础。

研究设计与样本

  • 可行性研究纳入10例蛛网膜下腔出血患者,每例接受5次序列图像引导经颅多普勒超声检查;利用计算机断层扫描血管造影数据规划至幕下和幕上脑动脉的轨迹并载入追踪多普勒探头的图像引导装置。

主要发现

  • 预规划靶点与最佳靶点间的平均距离为4.8±2.1 mm(首次检查),提示高空间精确性。
  • 空间精确性随血管靶点深度增加而下降。
  • 所有患者中,图像引导经颅多普勒超声检测到所有预定义的幕上和幕下血管节段。
  • 序列检查中空间精确性无显著变化,提示高可重复性。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and-for comparison-supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. METHODS: The study included 10 SAH patients, who each received 5 serial image-guided TCD examinations. Using computed tomography angiography data, trajectories to the infratentorial and supratentorial cerebral arteries were planned and loaded into an image guidance device tracking the Doppler probe. As a measure of spatial precision and spatial reproducibility, we analyzed the distances between the positions of preplanned vascular targets and optimal Doppler signals. RESULTS: The mean distance between preplanned and optimal target points was 4.8 ± 2.1 mm (first exam), indicating high spatial precision. The spatial precision decreased with increasing depth of the vascular target. In all patients, image-guided TCD detected all predefined supratentorial and infratentorial vascular segments. There were no significant changes in spatial precision in serial exams, indicating high reproducibility. CONCLUSIONS: Image-guided TCD is feasible for supratentorial and infratentorial arteries. It shows high spatial precision and reproducibility. This study provides a basis for future clinical studies on image-guided TCD for post-SAH vasospasm screening.