文献速递功能神经外科

术中磁共振引导苍白球脑深部电刺激治疗肌张力障碍的临床结局

Clinical outcomes of pallidal deep brain stimulation for dystonia implanted using intraoperative MRI.
PubMed 文献 · J Neurosurg · 2019-10-11

该研究评估了术中磁共振(iMRI)靶向平台植入苍白球内侧部(GPi)电极治疗肌张力障碍的临床结局与靶向精度,共植入60根电极于30例患者,轴位靶向精度为0.93±0.12 mm;19例纳入临床结局分析的患者BFMDRS评分6个月平均改善51.9%±9.7%、1年改善63.4%±8.0%,13例以颈部肌张力障碍为主的患者TWSTRS评分6个月改善53.3%±10.5%、1年改善67.6%±9.0%;6例患者(20%)发生严重并发症,涉及60根电极中的8根(13.3%)。

要点

  • iMRI引导GPi电极植入轴位靶向精度为0.93±0.12 mm。
  • 19例肌张力障碍患者BFMDRS评分6个月改善51.9%±9.7%,1年改善63.4%±8.0%。
  • 6例患者(20%)发生严重并发症,涉及8/60根电极(13.3%)。

核心结论

  • 术中磁共振引导电极植入在肌张力障碍患者中显示出与既往报道的清醒微电极记录引导植入相当的临床结局改善。
  • 电极植入精度高,大多数患者耐受良好。
  • 但部分患者经历了严重不良事件,归因于在繁忙的神经外科实践中引入新技术,并导致了方案、产品说明书和现场培训的修订。

研究设计与样本

  • 研究纳入接受iMRI引导GPi电极植入的肌张力障碍患者,排除既往接受过毁损或微电极记录引导手术的患者进行临床结局分析。
  • 共30例患者植入60根电极,其中19例纳入临床结局分析(特发性局灶性7例、特发性节段性5例、DYT1 1例、迟发性2例、其他继发性4例)。
  • 评估术前及术后6个月、12个月的Burke-Fahn-Marsden肌张力障碍评定量表(BFMDRS)评分和Toronto Western痉挛性斜颈评定量表(TWSTRS)评分,并分析电极精度、并发症/不良事件和刺激参数。
  • 进一步回顾了作者所在机构所有接受iMRI引导DBS的患者,包括额外53例因帕金森病接受GPi-DBS的患者。

主要发现

  • 轴位平面立体定向电极精度为距预期靶点0.93±0.12 mm。
  • 19例患者BFMDRS评分6个月平均改善51.9%±9.7%,1年改善63.4%±8.0%。
  • 13例以颈部肌张力障碍为主的患者TWSTRS评分6个月改善53.3%±10.5%,1年改善67.6%±9.0%。
  • 6例患者(20%)发生严重并发症,涉及60根植入电极中的8根(13.3%)。
  • 在扩大队列中,11例患者(13.3%)发生严重并发症,涉及15根电极(10.1%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Lead placement for deep brain stimulation (DBS) using intraoperative MRI (iMRI) relies solely on real-time intraoperative neuroimaging to guide electrode placement, without microelectrode recording (MER) or electrical stimulation. There is limited information, however, on outcomes after iMRI-guided DBS for dystonia. The authors evaluated clinical outcomes and targeting accuracy in patients with dystonia who underwent lead placement using an iMRI targeting platform. METHODS: Patients with dystonia undergoing iMRI-guided lead placement in the globus pallidus pars internus (GPi) were identified. Patients with a prior ablative or MER-guided procedure were excluded from clinical outcomes analysis. Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS) scores and Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS) scores were assessed preoperatively and at 6 and 12 months postoperatively. Other measures analyzed include lead accuracy, complications/adverse events, and stimulation parameters. RESULTS: A total of 60 leads were implanted in 30 patients. Stereotactic lead accuracy in the axial plane was 0.93 ± 0.12 mm from the intended target. Nineteen patients (idiopathic focal, n = 7; idiopathic segmental, n = 5; DYT1, n = 1; tardive, n = 2; other secondary, n = 4) were included in clinical outcomes analysis. The mean improvement in BFMDRS score was 51.9% ± 9.7% at 6 months and 63.4% ± 8.0% at 1 year. TWSTRS scores in patients with predominant cervical dystonia (n = 13) improved by 53.3% ± 10.5% at 6 months and 67.6% ± 9.0% at 1 year. Serious complications occurred in 6 patients (20%), involving 8 of 60 implanted leads (13.3%). The rate of serious complications across all patients undergoing iMRI-guided DBS at the authors' institution was further reviewed, including an additional 53 patients undergoing GPi-DBS for Parkinson disease. In this expanded cohort, serious complications occurred in 11 patients (13.3%) involving 15 leads (10.1%). CONCLUSIONS: Intraoperative MRI-guided lead placement in patients with dystonia showed improvement in clinical outcomes comparable to previously reported results using awake MER-guided lead placement. The accuracy of lead placement was high, and the procedure was well tolerated in the majority of patients. However, a number of patients experienced serious adverse events that were attributable to the introduction of a novel technique into a busy neurosurgical practice, and which led to the revision of protocols, product inserts, and on-site training.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Sharma VD, Bezchlibnyk YB, Isbaine F, et al. Clinical outcomes of pallidal deep brain stimulation for dystonia implanted using intraoperative MRI. J Neurosurg. 2019. PMID: 31604331. doi:10.3171/2019.6.JNS19548

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。