文献速递神经肿瘤功能神经外科

ZOOMit-BOLD 序列用于运动皮层定位的新方法

A Novel Sequence: ZOOMit-Blood Oxygen Level-Dependent for Motor-Cortex Localization.
PubMed 文献 · Neurosurgery · 2020-01-01

本研究纳入 20 例累及感觉运动区的胶质瘤患者,比较 ZOOMit-BOLD 与常规 BOLD-fMRI 定位手运动皮层的准确性,以术中直接皮层电刺激验证。ZOOMit-BOLD 定位准确率为 100%,常规 BOLD 仅 65%;无论胶质瘤是否直接侵犯手结,ZOOMit-BOLD 的重叠指数均更高。

要点

  • ZOOMit-BOLD 定位手运动皮层准确率 100%,优于常规 BOLD 的 65%。
  • 胶质瘤直接侵犯手结时,ZOOMit-BOLD 重叠指数仍高于常规 BOLD(P = .008)。
  • 胶质瘤未侵犯手结时,ZOOMit-BOLD 重叠指数也更高(P = .004)。

核心结论

  • ZOOMit-BOLD 可能替代常规 BOLD 用于识别手运动皮层,尤其适用于胶质瘤直接侵犯手结的病例。

研究设计与样本

  • 研究纳入 20 例累及感觉运动区的胶质瘤患者,分别用 ZOOMit-BOLD 和常规 BOLD 定位手运动皮层,并以术中直接皮层电刺激验证。
  • 根据胶质瘤是否直接侵犯或邻近影响手结,患者被分为受累组和未受累组。
  • 采用重叠指数评估手运动皮层定位的准确性,重叠指数等于 0 定义为定位不准确。

主要发现

  • ZOOMit-BOLD 定位运动皮层的准确率为 100%,常规 BOLD 仅为 65%。
  • 无论胶质瘤是否直接侵犯手结,ZOOMit-BOLD 的平均重叠指数均高于常规 BOLD:直接侵犯组 P = .008,未侵犯组 P = .004。
  • 受累组重叠指数显著低于未受累组:ZOOMit-BOLD P = .002,常规 BOLD P < .001。

临床怎么用

  • 对于累及感觉运动区的胶质瘤,尤其是直接侵犯手结的病例,可考虑采用 ZOOMit-BOLD 辅助术前手运动皮层定位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Use of conventional blood oxygen level-dependent functional magnetic resonance imaging (conventional-BOLD-fMRI) presents challenges in accurately identifying the hand-motor cortex when a glioma involves the ipsilateral hand-knob. Zoomed imaging technique with parallel transmission (ZOOMit)-BOLD is a novel sequence allowing high spatial resolution with a relatively small field of view that may solve this problem. OBJECTIVE: To compare the accuracy of ZOOMit-BOLD and conventional-BOLD in hand-motor cortex identification. METHODS: A total of 20 patients with gliomas involving the sensorimotor cortex were recruited to identify the hand-motor cortex by both ZOOMit-BOLD and conventional-BOLD. Based on whether the entire or partial glioma directly invaded (was located within) the hand-knob or indirectly affected it by proximity, patients were placed into the involved or uninvolved groups, respectively. Direct cortical stimulation was applied intraoperatively to verify the location of the hand-motor cortex. Overlap indices were used to evaluate the accuracy of the hand-motor cortex identification. An overlap index equal to 0, indicating lack of overlap, was classified as inaccurate classification. RESULTS: The accuracy of motor-cortex identification with ZOOMit-BOLD was 100% compared to only 65% with conventional-BOLD. The average overlap index yielded by ZOOMit-BOLD was higher than that of conventional-BOLD, regardless of whether gliomas directly invaded the hand-knob (P = .008) or not (P = .004). The overlap index in the involved group was significantly lower than that in the uninvolved group with both ZOOMit-BOLD (P = .002) and conventional-BOLD (P < .001). CONCLUSION: ZOOMit-BOLD may potentially replace conventional-BOLD to identify the hand-motor cortex, particularly in cases in which gliomas directly invade the hand-knob.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Fang S, Bai HX, Fan X, et al. A Novel Sequence: ZOOMit-Blood Oxygen Level-Dependent for Motor-Cortex Localization. Neurosurgery. 2020. PMID: 31642505. doi:10.1093/neuros/nyz441

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。