文献速递脑血管病外科神经重症

定量磁共振静脉成像用于颅内动静脉分流病变疗效监测

Monitoring Treatment Effectiveness in Intracranial Arteriovenous Shunt Lesions: Emerging Role of Quantitative Magnetic Resonance Venography for Intracranial Arteriovenous Shunts.
PubMed 文献 · World Neurosurg · 2019-10-23

本文报道2例症状性颅内动静脉分流患者(61岁男性左侧横窦-乙状窦硬脑膜动静脉瘘、40岁女性左侧顶叶动静脉畸形),采用NOVA定量MRV(qMRV)监测治疗前后颅内静脉流出量。两例在分流病变被治疗闭塞后均显示颅内静脉流出显著减少,并伴明显临床改善。作者认为这是NOVA qMRV在成人颅内动静脉畸形或硬脑膜动静脉瘘中的首次成功临床应用报告,提示其可用于无创测量颅内及颅外静脉血流并监测疗效。

要点

  • NOVA qMRV可无创测量颅内静脉流出,用于颅内动静脉分流病变治疗前后监测。
  • 2例分流病变闭塞后qMRV示颅内静脉流出显著减少,伴临床明显改善。
  • 作者提出qMRV是监测颅内动静脉分流病变疗效的有前景技术。

核心结论

  • NOVA qMRV是有前景的无创颅内及颅外静脉血流测量技术,可用于监测颅内动静脉分流病变的治疗效果。

研究设计与样本

  • 病例报告,纳入2例症状性颅内动静脉分流患者:1例61岁男性左侧横窦-乙状窦硬脑膜动静脉瘘,1例40岁女性左侧顶叶动静脉畸形。

主要发现

  • 两例患者在分流病变被治疗闭塞后,NOVA qMRV均显示颅内静脉流出显著减少。
  • 两例患者静脉流出减少同时伴明显临床改善。

临床怎么用

  • 可考虑用NOVA qMRV无创测量颅内静脉血流,辅助监测颅内动静脉分流病变治疗后的血流动力学变化。

局限性

  • 仅为2例病例报告,NOVA qMRV在神经血管实践中的应用仍很少,需更多研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Quantitative magnetic resonance angiography (qMRA) using noninvasive optimal vessel analysis (NOVA) is a novel noninvasive imaging technique that is being increasingly used to measure blood flow in extracranial and intracranial arteries. By providing important quantitative flow data, NOVA qMRA can facilitate the management of cerebrovascular disease. While the same technology can also be applied to measure flow in intracranial and extracranial veins, NOVA quantitative MRV (qMRV) is only rarely used in neurovascular practice. CASE DESCRIPTION: We report interesting qMRV data in 2 patients with symptomatic intracranial arteriovenous shunts: a 61-year-old man with a left transverse-sigmoid dural arteriovenous fistula and a 40-year-old woman with a left parietal arteriovenous malformation. In each patient, NOVA qMRV demonstrated significant reduction of intracranial venous outflow after therapeutic obliteration of the shunt lesion, heralding marked clinical improvement. CONCLUSIONS: To the best of our knowledge, this is the first report of successful clinical application of NOVA qMRV in adult patients with intracranial arteriovenous malformations or dural arteriovenous fistulas. We propose that NOVA qMRV is a promising technique for noninvasive measurement of intracranial and extracranial venous blood flow and for monitoring treatment effectiveness in patients with intracranial arteriovenous shunt lesions.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Fluss R, Chan AW, Ligas BA, et al. Monitoring Treatment Effectiveness in Intracranial Arteriovenous Shunt Lesions: Emerging Role of Quantitative Magnetic Resonance Venography for Intracranial Arteriovenous Shunts. World Neurosurg. 2019. PMID: 31655230. doi:10.1016/j.wneu.2019.10.088

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。