文献速递神经肿瘤

基于影像组学特征的自动化机器学习预测中线胶质瘤H3 K27M突变

Automated machine learning based on radiomics features predicts H3 K27M mutation in midline gliomas of the brain.
PubMed 文献 · Neuro Oncol · 2020-01-01

本研究回顾性纳入100例中线胶质瘤患者,从FLAIR图像提取影像组学特征,使用TPOT自动化机器学习流程构建预测模型。最佳模型在测试队列AUC为0.903,独立验证队列AUC为0.85,表明常规MRI影像组学联合autoML可高判别度预测H3 K27M突变状态。

要点

  • 常规MRI无法识别H3 K27M突变状态,影像组学联合autoML可辅助预测。
  • 最佳模型测试队列AUC 0.903,独立验证队列AUC 0.85。
  • 研究为单中心回顾性设计,样本量有限,需进一步外部验证。

核心结论

  • 基于常规MRI影像组学特征的autoML分类器可高判别度预测中线胶质瘤H3 K27M突变状态。

研究设计与样本

  • 单中心回顾性研究,纳入100例中线胶质瘤患者,其中H3 K27M突变40例、野生型60例。
  • 从FLAIR图像提取影像组学特征,数据集随机分层为75%训练队列和25%测试队列。
  • 采用TPOT优化机器学习流程并筛选重要影像组学特征,比较10个独立TPOT生成模型。
  • 另用22例独立队列验证最佳模型。

主要发现

  • TPOT生成10个预测模型,最佳流程准确率在训练队列为0.788至0.867,在测试队列为0.60至0.84。
  • 最终模型在测试队列的AUC为0.903,平均精度为0.911。
  • 最佳模型在独立验证队列的AUC为0.85,平均精度为0.855。

临床怎么用

  • 对于中线胶质瘤患者,可利用常规MRI FLAIR图像的影像组学特征联合autoML辅助预测H3 K27M突变状态。
  • 该模型可作为无创辅助工具,但需在更大样本和多中心数据中验证后方可用于临床决策。

局限性

  • 单中心回顾性研究,样本量有限。
  • 验证队列仅22例,样本量较小。
  • 仅基于FLAIR图像提取影像组学特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Conventional MRI cannot be used to identify H3 K27M mutation status. This study aimed to investigate the feasibility of predicting H3 K27M mutation status by applying an automated machine learning (autoML) approach to the MR radiomics features of patients with midline gliomas. METHODS: This single-institution retrospective study included 100 patients with midline gliomas, including 40 patients with H3 K27M mutations and 60 wild-type patients. Radiomics features were extracted from fluid-attenuated inversion recovery images. Prior to autoML analysis, the dataset was randomly stratified into separate 75% training and 25% testing cohorts. The Tree-based Pipeline Optimization Tool (TPOT) was applied to optimize the machine learning pipeline and select important radiomics features. We compared the performance of 10 independent TPOT-generated models based on training and testing cohorts using the area under the curve (AUC) and average precision to obtain the final model. An independent cohort of 22 patients was used to validate the best model. RESULTS: Ten prediction models were generated by TPOT, and the accuracy obtained with the best pipeline ranged from 0.788 to 0.867 for the training cohort and from 0.60 to 0.84 for the testing cohort. After comparison, the AUC value and average precision of the final model were 0.903 and 0.911 in the testing cohort, respectively. In the validation set, the AUC was 0.85, and the average precision was 0.855 for the best model. CONCLUSIONS: The autoML classifier using radiomics features of conventional MR images provides high discriminatory accuracy in predicting the H3 K27M mutation status of midline glioma.

来源:Neuro Oncol,查看原文。版权归原作者所有。

引用

  1. Su X, Chen N, Sun H, et al. Automated machine learning based on radiomics features predicts H3 K27M mutation in midline gliomas of the brain. Neuro Oncol. 2020. PMID: 31563963. doi:10.1093/neuonc/noz184