文献速递神经肿瘤功能神经外科

颅脑神经外科术中获取DTI:读出分段DTI与标准单次激发DTI的比较

Intraoperative acquisition of DTI in cranial neurosurgery: readout-segmented DTI versus standard single-shot DTI.
PubMed 文献 · J Neurosurg · 2019-08-16

本研究在22例成人颅内肿瘤或局灶性皮质发育不良患者中,比较3T术中MRI环境下读出分段(RS)DTI与标准单次激发(SS)DTI的质量与纤维束成像成功率。RS-iDTI在易感伪影区域(切除腔、眶额及前颞皮质)的伪影更少,平均解剖偏差为2.7±0.2 mm,而SS-iDTI为7.5±0.4 mm;SS-iDTI在8/22(36%)患者中因伪影导致至少1条手术相关纤维束重建失败,其中5例RS-iDTI成功重建。结论:RS EPI可在开放颅脑术中3T环境下为主白质纤维束提供更高质量和更准确的DTI纤维束成像。

要点

  • RS-iDTI在易感伪影区(切除腔、眶额、前颞)的伪影较SS-iDTI少。
  • RS-iDTI平均解剖偏差2.7±0.2 mm,SS-iDTI为7.5±0.4 mm。
  • SS-iDTI在8/22(36%)患者中因伪影致至少1条手术相关纤维束重建失败。

核心结论

  • 在3T术中开放颅脑神经外科应用中,RS EPI较SS EPI能获得更高质量、更准确的DTI纤维束成像,用于主要白质纤维束的手术相关示踪。

研究设计与样本

  • 对22例因疑似低级别胶质瘤(14例,64%)、高级别胶质瘤(7例,32%)或局灶性皮质发育不良接受颅内iMRI切除的成人患者,采集术前及术中3T 3D T1加权、2D多层RS-iDTI(Siemens平台称RESOLVE)和SS-iDTI图像。
  • 比较两种iDTI序列的区域易感伪影、相对T1加权成像的解剖偏差、手术相关纤维束的纤维束成像输出,以及相对术前DTI的术中纤维束移位。

主要发现

  • RS-iDTI在切除腔、眶额皮质和前颞皮质等区域定性显示更少的易感伪影。
  • 在最易出现易感伪影的区域,RS-iDTI平均解剖偏差为2.7±0.2 mm,SS-iDTI为7.5±0.4 mm。
  • 两种DTI方法的纤维束重建成功率无显著差异,但SS-iDTI在8/22(36%)患者中因易感伪影导致至少1条手术相关纤维束纤维束成像失败,其中5/8例RS-iDTI成功重建。
  • 在两种序列均成功纤维束成像的病例中,序列间最大差异显著(平均9.5±5.7 mm,范围-27.1至18.7 mm)。

临床怎么用

  • 在开放颅脑术中3T iMRI环境下,可优先考虑RS EPI DTI以改善手术相关白质纤维束的成像质量和准确性。
  • 对于SS-iDTI因易感伪影导致纤维束重建失败的病例,RS-iDTI可能有助于成功重建手术相关纤维束。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Diffusion tensor imaging (DTI) tractography is commonly used in neurosurgical practice but is largely limited to the preoperative setting. This is due primarily to image degradation caused by susceptibility artifact when conventional single-shot (SS) echo-planar imaging (EPI) DTI (SS-DTI) is acquired for open cranial, surgical position intraoperative DTI (iDTI). Readout-segmented (RS) EPI DTI (RS-DTI) has been reported to reduce such artifact but has not yet been evaluated in the intraoperative MRI (iMRI) environment. The authors evaluated the performance of RS versus SS EPI for DTI of the human brain in the iMRI setting. METHODS: Pre- and intraoperative 3-T 3D T1-weighted and 2D multislice RS-iDTI (called RESOLVE [readout segmentation of long variable echo-trains] on the Siemens platform) and SS-iDTI images were acquired in 22 adult patients undergoing intraaxial iMRI resections for suspected low-grade glioma (14; 64%), high-grade glioma (7; 32%), or focal cortical dysplasia. Regional susceptibility artifact, anatomical deviation relative to T1-weighted imaging, and tractographic output for surgically relevant tracts were compared between iDTI sequences as well as the intraoperative tract shifts from preoperative DTI. RESULTS: RS-iDTI resulted in qualitatively less regional susceptibility artifact (resection cavity, orbitofrontal and anterior temporal cortices) and mean anatomical deviation in regions most prone to susceptibility artifact (RS-iDTI 2.7 ± 0.2 vs SS-iDTI 7.5 ± 0.4 mm) compared to SS-iDTI. Although tract reconstruction success did not significantly differ by DTI method, susceptibility artifact-related tractography failure (of at least 1 surgically relevant tract) occurred for SS-iDTI in 8/22 (36%) patients, and in 5 of these 8 patients RS-iDTI permitted successful reconstruction. Among cases with successful tractography for both sequences, maximal intersequence differences were substantial (mean 9.5 ± 5.7 mm, range -27.1 to 18.7 mm). CONCLUSIONS: RS EPI enables higher quality and more accurate DTI for surgically relevant tractography of major white matter tracts in intraoperative, open cranium neurosurgical applications at 3 T.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Elliott CA, Danyluk H, Aronyk KE, et al. Intraoperative acquisition of DTI in cranial neurosurgery: readout-segmented DTI versus standard single-shot DTI. J Neurosurg. 2019. PMID: 31419798. doi:10.3171/2019.5.JNS19890

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。