文献速递神经肿瘤

ABC/2估算法与计算机体积法测量脑膜瘤体积的比较

Comparison of ABC/2 estimation and a volumetric computerized method for measurement of meningiomas using magnetic resonance imaging.
PubMed 文献 · J Neurooncol · 2019-08-10

该研究回顾性纳入2005-2015年VCU脑与脊柱肿瘤登记中保守治疗至少1.5年的脑膜瘤患者,比较简化椭球(ABC/2)法与计算机周径体积法测量肿瘤体积的一致性。共29个肿瘤、146幅图像,两法平均体积分别为3.2±3.4 cm³和3.4±3.5 cm³,平均差0.2 cm³(P=0.10),一致性相关系数0.95(95%CI 0.91,0.98),但周径法有16%图像无法测量。

要点

  • ABC/2法与计算机周径法测量脑膜瘤体积一致性极好,CCC为0.95。
  • 两法平均体积差仅0.2 cm³,差异无统计学意义(P=0.10)。
  • 周径法在约六分之一图像上无法完成测量,ABC/2法更具可操作性。

核心结论

  • 简化椭球(ABC/2)法与计算机周径体积法测量保守治疗的脑膜瘤体积具有极好相关性。
  • ABC/2法仍是脑膜瘤体积评估的优秀方法,且较周径法有优势。

研究设计与样本

  • 回顾性研究,从VCU脑与脊柱肿瘤登记中纳入2005-2015年保守治疗至少1.5年的脑膜瘤患者。
  • 共26例患者、29个肿瘤、146幅图像,分别用ABC/2法和计算机周径法独立测量体积,行组内相关与Bland-Altman分析。

主要发现

  • ABC/2法与周径法的平均体积分别为3.2±3.4 cm³和3.4±3.5 cm³。
  • 两法平均体积差为0.2 cm³(SE=0.12;P=0.10)。
  • 两法一致性相关系数为0.95(95%CI 0.91,0.98)。
  • 146幅图像中有24幅(16%)用周径法无法测量。

临床怎么用

  • 对保守治疗的脑膜瘤随访,可用ABC/2法估算体积,其与计算机周径法高度一致。
  • 周径法在部分图像上无法测量时,ABC/2法可作为替代或补充。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Measurement of tumor growth rates over time for patients with meningiomas has important prognostic and therapeutic implications. Our objective was to compare two methods of measuring meningioma volume: (1) the simplified ellipsoid (ABC/2) method; and (2) perimetric volume measurements using imaging software modules. METHODS: Patients with conservatively managed meningiomas for at least 1.5 years were retrospectively identified from the VCU Brain and Spine Tumor Registry over a 10-year period (2005-2015). Tumor volumes were independently measured using the simplified ellipsoid and computerized perimetric methods. Intra class correlations (CC) and Bland-Altman analyses were performed. RESULTS: A total of 26 patients representing 29 tumors were identified. Across 146 images, there were 24 (16%) images that were non-measurable using standard application commands with the computerized perimetric method. The mean volume obtained using the ABC/2 and computerized perimetric methods were 3.2 ± 3.4 cm3 and 3.4 ± 3.5 cm3, respectively. The mean volume difference was 0.2 cm3 (SE = 0.12; p = 0.10) across measurement methods. The concordance correlation coefficient (CCC) between methods was 0.95 (95% CI 0.91, 0.98). CONCLUSIONS: There is excellent correlation between the simplified ellipsoid and computerized perimetric methods of volumetric analysis for conservatively managed meningiomas. The simplified ellipsoid method remains an excellent method for meningioma volume assessment and had an advantage over the perimetric method which failed to allow measurement of roughly one in six tumors on imaging.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Opalak CF, Parry M, Rock AK, et al. Comparison of ABC/2 estimation and a volumetric computerized method for measurement of meningiomas using magnetic resonance imaging. J Neurooncol. 2019. PMID: 31401721. doi:10.1007/s11060-019-03205-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。