血流导向装置重塑Willis环治疗梭形大脑前动脉动脉瘤
本文报道一例25岁男性右侧大脑前动脉A1段9×5.5 mm梭形动脉瘤,采用Pipeline栓塞装置从右侧大脑前动脉至右侧大脑中动脉释放,将病变载瘤动脉隔离,实现血管内动脉瘤隔绝。6个月随访患者无症状,血管造影示装置通畅、动脉瘤近完全闭塞,右侧A2段经前交通动脉侧支代偿保持通畅。
要点
- 梭形动脉瘤缺乏明确瘤颈,血管内血流导向装置可作为外科治疗的替代方案。
- Pipeline装置跨右侧ACA至右侧MCA释放可隔离A1段梭形动脉瘤。
- 6个月随访示装置通畅、动脉瘤近完全闭塞且A2段经侧支代偿通畅。
核心结论
- Pipeline栓塞装置可通过重塑Willis环有效治疗前循环梭形动脉瘤。
研究设计与样本
- 单例病例技术报告:25岁男性,右侧ACA A1段9×5.5 mm梭形动脉瘤,接受血管内Pipeline栓塞装置治疗。
主要发现
- Pipeline装置从右侧ACA至右侧MCA释放,将右侧ACA A1段隔离。
- 6个月随访患者无症状、头痛缓解,血管造影示装置通畅、右侧ACA A1段近完全闭塞。
- 右侧ACA A2段经前交通动脉侧支血流保持通畅,MRI证实上述发现。
关键数值与推荐
- 动脉瘤尺寸为9×5.5 mm,位于右侧ACA A1段,呈梭形。
- 随访时间为6个月,造影示动脉瘤近完全闭塞。
临床怎么用
- 对缺乏明确瘤颈的前循环梭形动脉瘤,可考虑血流导向装置隔离载瘤动脉并依赖侧支代偿。
- 术后需影像随访评估装置通畅性、动脉瘤闭塞程度及侧支循环。
局限性
- 本文为单例病例报告,技术可行性与疗效需更大样本验证。
- 随访时间仅6个月,长期闭塞率与侧支代偿持久性未明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fusiform aneurysms are challenging lesions to manage given their poorly understood natural history and lack of a distinct neck. Historically, they have been treated surgically but endovascular management has recently evolved as a viable alternative. In this case, we describe a novel flow diversion technique for treatment of a fusiform anterior cerebral artery (ACA) aneurysm by jailing the compromised parent vessel obtaining endovascular aneurysm trapping. METHODS: A 25-year-old man underwent brain magnetic resonance imaging and magnetic resonance angiography for workup of a headache, which revealed a fusiform right ACA A1 segment aneurysm. The patient subsequently underwent catheter digital subtraction angiography, which confirmed a 9 × 5.5 mm fusiform right ACA A1 segment aneurysm. The patient elected to undergo endovascular treatment. A Pipeline Embolization Device (Medtronic, Dublin, Ireland) was placed from the right anterior cerebral artery to the right middle cerebral artery, thereby jailing the right ACA A1 segment. RESULTS: At 6-month follow-up, the patient was asymptomatic and his headache had resolved. An angiogram was obtained, showing patency of the Pipeline Embolization Device and near complete occlusion of the right ACA A1 segment. The right ACA A2 segment remained patent via collateral flow through the anterior communicating artery. These findings were confirmed on magnetic resonance imaging. The patient remained asymptomatic for the duration of the follow-up. CONCLUSIONS: This case illustrates the efficacy of the Pipeline Embolization Device for treatment of a fusiform anterior circulation aneurysm via remodeling the circle of Willis.
引用
- Griffin A, Cutler A, Gonzalez LF, et al. Treatment of a Fusiform Anterior Cerebral Artery Aneurysm by Remodeling the Circle of Willis with Flow Diversion: A Novel Technical Note. World Neurosurg. 2019. PMID: 31426250. doi:10.1016/j.wneu.2019.05.245
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。