门诊遥测颅内压测量在分流依赖患者中的重测信度
本研究回顾性分析66组脑积水和特发性颅内高压分流术后患者遥测颅内压数据,采用站立-仰卧-坐位30分钟标准化范式,间隔至少24小时重复测量。结果显示总体重测信度优秀(Pearson相关系数0.99,P<0.001),各体位信度均高。
要点
- 站立-仰卧-坐位范式门诊遥测颅内压重测信度优秀(r=0.99)。
- 各体位信度:站立r=0.98,仰卧r=0.98,坐位r=0.99,均P<0.001。
- 高重测信度是临床决策的前提,支持该范式用于评估分流不足或过度。
核心结论
- 站立-仰卧-坐位范式在门诊遥测颅内压测量中具有高重测信度,应作为临床决策的前提。
研究设计与样本
- 回顾性分析66组脑积水和特发性颅内高压分流术后患者遥测颅内压数据,重复测量间隔至少24小时,采用Pearson相关分析评估重测信度。
主要发现
- 总体重测信度优秀,Pearson相关系数0.99(P<0.001)。
- 站立位相关系数0.98(P<0.001),仰卧位0.98(P<0.001),坐位0.99(P<0.001)。
- 重测差异平方和反映所有测试体位效度相当。
关键数值与推荐
- 站立-仰卧-坐位范式:每10分钟变换体位,共30分钟;先行走,再仰卧,最后坐位且头托抬高60°。
- 颅内压数据以均值±标准差(mmHg)报告。
临床怎么用
- 门诊可采用该标准化范式进行遥测颅内压记录,高重测信度支持用于确认分流不足或过度的临床怀疑。
局限性
- 回顾性研究设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Some patients with hydrocephalus and idiopathic intracranial hypertension treated for elevated intracranial pressure (ICP) with a cerebrospinal fluid shunt may continue to experience symptoms or develop new symptoms despite valve adjustments. Use of telemetric ICP measurements may help confirm clinical suspicion of cerebrospinal fluid underdrainage or overdrainage in these patients. However, point in time, duration, and activity during the measurements have never been standardized. We devised a simple, repeatable maneuver for outpatient telemetric ICP recording and evaluated its test-retest reliability. METHODS: Data of patients who underwent ventriculoperitoneal or ventriculoatrial shunt placement and subsequent telemetric ICP sensor implantation were retrospectively reviewed. Telemetric ICP recordings in patients were conducted in a standardized manner: The standing-supine-sitting paradigm requires postural changes in 10-minute intervals over 30 minutes. First, the patient is requested to walk; second, to lay down; third, to sit down with a headrest elevation of 60°. ICP data (in mmHg) were reported as mean ± SD values. Test-retest validity was assessed using Pearson correlation analysis. RESULTS: We evaluated 66 ICP datasets obtained repeatedly with a time difference of at least 24 hours. Overall test-retest reliability was excellent (Pearson correlation coefficient 0.99, P < 0.001), as were the scores for individual postures: standing (correlation 0.98, P < 0.001), supine (correlation 0.98, P < 0.001), and sitting (correlation 0.99, P < 0.001). The sum of square differences of the test-retest measures reflected a comparable validity of all tested positions. CONCLUSIONS: We confirmed high test-retest reliability of the standing-supine-sitting paradigm for telemetric ICP measurements in the outpatient setting. High test-retest reliability should be considered as prerequisite for clinical decision making.
引用
- Müller SJ, Freimann FB, von der Brelie C, et al. Test-Retest Reliability of Outpatient Telemetric Intracranial Pressure Measurements in Shunt-Dependent Patients with Hydrocephalus and Idiopathic Intracranial Hypertension. World Neurosurg. 2019. PMID: 31295619. doi:10.1016/j.wneu.2019.07.014