增强现实在硬膜内脊髓肿瘤手术中的应用
结果显示AR注册误差0.72±0.24 mm,肿瘤轮廓匹配良好,结论认为基于显微镜的AR可可靠应用于硬膜内脊髓肿瘤手术。
要点
- 基于显微镜的AR可可靠应用于硬膜内脊髓肿瘤手术。
- 自动AR注册精度高,总体注册误差0.72±0.24 mm。
- 术中CT注册剂量:颈椎0.22±0.16 mSv,胸椎1.68±0.61 mSv。
核心结论
- 基于显微镜的AR可可靠应用于硬膜内脊髓肿瘤手术。
- 自动AR注册确保高精度,并提供肿瘤范围及周围结构的直观可视化。
研究设计与样本
- AR通过手术显微镜的平视显示器(HUD)提供,采用低剂量术中CT实现用户无关的自动AR注册。
- 术前影像数据分割目标结构,应用非线性图像配准考虑脊柱灵活性。
主要发现
- 所有病例中AR通过可视化肿瘤轮廓和其他相关周围结构辅助手术。
- 总体AR注册误差为0.72±0.24 mm(均值±标准差),所有病例可见肿瘤轮廓与AR可视化匹配紧密。
- 注册扫描有效剂量:颈部病变0.22±0.16 mSv,胸部病变1.68±0.61 mSv。
- HUD AR使用时间占显微镜时间的平均比例为51.6±36.7%。
- HUD关闭再开启次数范围为2至17次(5.7±4.4次)。
临床怎么用
- 基于显微镜的AR可辅助硬膜内脊髓肿瘤手术中肿瘤轮廓及周围结构的可视化。
- 自动AR注册结合术中CT可提供高精度注册,支持术中直观定位。
- 该设置下颅脑AR的先进多模态选项也可应用于脊柱手术。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Microscope-based augmented reality (AR) is commonly used in cranial surgery; however, until recently, this technique was not implemented for spinal surgery. We prospectively investigated, how AR can be applied for intradural spinal tumor surgery. METHODS: For ten patients with intradural spinal tumors (ependymoma, glioma, hemangioblastoma, meningioma, and metastasis), AR was provided by head-up displays (HUDs) of operating microscopes. User-independent automatic AR registration was established by low-dose intraoperative computed tomography. The objects visualized by AR were segmented in preoperative imaging data; non-linear image registration was applied to consider spine flexibility. RESULTS: In all cases, AR supported surgery by visualizing the tumor outline and other relevant surrounding structures. The overall AR registration error was 0.72 ± 0.24 mm (mean ± standard deviation), a close matching of visible tumor outline and AR visualization was observed for all cases. Registration scanning resulted in a low effective dose of 0.22 ± 0.16 mSv for cervical and 1.68 ± 0.61 mSv for thoracic lesions. The mean HUD AR usage in relation to microscope time was 51.6 ± 36.7%. The HUD was switched off and turned on again in a range of 2 to 17 times (5.7 ± 4.4 times). Independent of the status of the HUD, the AR visualization was displayed on monitors throughout surgery. CONCLUSIONS: Microscope-based AR can be reliably applied to intradural spinal tumor surgery. Automatic AR registration ensures high precision and provides an intuitive visualization of the extent of the tumor and surrounding structures. Given this setting, all advanced multi-modality options of cranial AR can also be applied to spinal surgery.
引用
- Carl B, Bopp M, Saß B, et al. Augmented reality in intradural spinal tumor surgery. Acta Neurochir (Wien). 2019. PMID: 31300886. doi:10.1007/s00701-019-04005-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。