文献速递脑血管病外科神经重症

全脑四维CTA评估颅内静脉血流动力学的临床验证

A Novel Flow Dynamics Study of the Intracranial Veins Using Whole Brain Four-Dimensional Computed Tomography Angiography.
PubMed 文献 · World Neurosurg · 2019-07-19

本研究回顾性分析26例患者共97条静脉,对比四维CTA与常规DSA评估颅内静脉血流方向与速度。四维CTA判断的血流方向与DSA一致率为94.8%,动静脉分流影响的顺行与逆行通道平均流速分别为64.3 mm/s和81.8 mm/s。该方法可靠,具有临床应用潜力。

要点

  • 四维CTA可评估颅内静脉血流方向与速度。
  • 四维CTA与DSA的血流方向一致率为94.8%。
  • 动静脉分流通道顺行流速64.3 mm/s,逆行81.8 mm/s。

核心结论

  • 基于四维CTA的血流分析可评估颅内静脉血流方向与速度,除部分局限外方法可靠且具临床潜力。

研究设计与样本

  • 回顾性分析26例同时接受四维CTA与常规DSA检查的患者,共97条静脉,含16例动静脉分流疾病、9例颅内肿瘤和1例脑动脉瘤。

主要发现

  • 四维CTA判断的血流方向与常规DSA一致率为94.8%。
  • 受动静脉分流影响的顺行通道平均静脉流速为64.3 mm/second,逆行通道为81.8 mm/second。

关键数值与推荐

  • 采用四维CTA分析时间-密度曲线并进行伽马分布外推,获得每条静脉的血流方向与流速。

临床怎么用

  • 四维CTA可作为评估颅内静脉血流方向与速度的临床工具,用于理解颅内生理与病理生理。

局限性

  • 原文提及该方法存在一些局限性,但未具体说明。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The flow dynamics of the intracranial venous channels are fundamentally important for understanding intracranial physiology and pathophysiology. However, the method clinically applicable to the evaluation of the flow dynamics of the intracranial venous system has not been well described in the reported data. We have developed a new method to evaluate intracranial venous flow direction and velocity using 4-dimensional (4D) computed tomography angiography (CTA). The aim of the present study was to verify the accuracy and validity of 4D-CTA in a clinical setting. METHODS: We retrospectively analyzed 97 veins from 26 patients (16 cases of arteriovenous shunt disease, 9 intracranial tumor cases, and 1 cerebral aneurysm case) who had undergone both 4D-CTA and conventional digital subtraction angiography (DSA). Using 4D-CTA, we analyzed the time-density curve with gamma distribution extrapolation and obtained the direction of the flow and flow velocity of each vein. The direction of the flow in 4D-CTA was also collated with that obtained using conventional DSA to verify the experimental method. RESULTS: The direction of the flow determined by 4D-CTA was consistent with that of conventional DSA in 94.8% of cases. The average venous flow velocity was 64.3 mm/second and 81.8 mm/second, respectively, in the antegrade and retrograde channels affected by arteriovenous shunts. CONCLUSIONS: The present flow analysis using 4D-CTA enabled us to evaluate the direction and velocity of intracranial venous flow. Other than some limitations, the presented method is reliable and its potential for application in clinical settings is promising.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Mizutani K, Arai N, Toda M, et al. A Novel Flow Dynamics Study of the Intracranial Veins Using Whole Brain Four-Dimensional Computed Tomography Angiography. World Neurosurg. 2019. PMID: 31330333. doi:10.1016/j.wneu.2019.07.109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。