超声视神经鞘直径与去骨瓣减压术后ICP的相关性及无创替代测量准确性

Ultrasonographic optic nerve sheath diameter correlation with ICP and accuracy as a tool for noninvasive surrogate ICP measurement in patients with decompressive craniotomy.
PubMed 文献 · J Neurosurg · 2019-07-19

本研究在35例重型颅脑损伤去骨瓣减压术后患者中,于术后6小时和24小时同步行床旁超声测量视神经鞘直径(ONSD)与有创颅内压(ICP)监测,并以40例健康成人作对照。结果显示ONSD与ICP呈显著线性相关(r=0.771,p<0.0001),ONSD增大可有效预测ICP升高,提示超声ONSD可作为去骨瓣减压术后无创评估ICP的敏感方法。

要点

  • 去骨瓣减压术后ONSD与有创ICP呈显著正相关(r=0.771)。
  • ONSD cutoff 5.48 mm预测ICP>13 mm Hg,敏感度91.1%、特异度88.0%。
  • ONSD cutoff 5.83 mm预测ICP>22 mm Hg,敏感度94.4%、特异度81.0%。

核心结论

  • 超声测量的ONSD与有创ICP测量值强相关,可能作为去骨瓣减压术后重型颅脑损伤患者检测ICP升高的敏感无创方法。

研究设计与样本

  • 另纳入40例健康成人作为对照,测量其ONSD。
  • 患者按ICP水平分为正常组(ICP≤13 mm Hg)、轻度升高组(ICP=14-22 mm Hg)和重度升高组(ICP>22 mm Hg)。

主要发现

  • 对照组平均ONSD为4.09±0.38 mm;正常、轻度升高、重度升高ICP组平均ONSD分别为4.92±0.37、5.77±0.41、6.52±0.44 mm(p<0.001)。
  • ONSD与ICP之间存在显著线性相关(r=0.771,p<0.0001)。
  • ONSD增大是ICP升高的强预测因子。

关键数值与推荐

  • ONSD cutoff为5.48 mm时(预测ICP>13 mm Hg),敏感度91.1%、特异度88.0%。
  • ONSD cutoff为5.83 mm时(预测ICP>22 mm Hg),敏感度94.4%、特异度81.0%。

临床怎么用

  • 对去骨瓣减压术后重型颅脑损伤患者,可采用床旁超声测量ONSD作为无创辅助手段筛查ICP升高。
  • ONSD 5.48 mm和5.83 mm两个cutoff可分别用于提示ICP>13 mm Hg和ICP>22 mm Hg。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Increased intracranial pressure (ICP) results in enlarged optic nerve sheath diameter (ONSD). In this study the authors aimed to assess the association of ONSD and ICP in severe traumatic brain injury (TBI) after decompressive craniotomy (DC). METHODS: ONSDs were measured by ocular ultrasonography in 40 healthy control adults. ICPs were monitored invasively with a microsensor at 6 hours and 24 hours after DC operation in 35 TBI patients. ONSDs were measured at the same time in these patients. Patients were assigned to 3 groups according to ICP levels, including normal (ICP ≤ 13 mm Hg), mildly elevated (ICP = 14-22 mm Hg), and severely elevated (ICP > 22 mm Hg) groups. ONSDs were compared between healthy control adults and TBI cases with DC. Then, the association of ONSD with ICP was analyzed using Pearson's correlation coefficient, linear regression analysis, and receiver operator characteristic curves. RESULTS: Seventy ICP measurements were obtained among 35 TBI patients after DC, including 25, 27, and 18 measurements in the normal, mildly elevated, and severely elevated ICP groups, respectively. Mean ONSDs were 4.09 ± 0.38 mm in the control group and 4.92 ± 0.37, 5.77 ± 0.41, and 6.52 ± 0.44 mm in the normal, mildly elevated, and severely elevated ICP groups, respectively (p < 0.001). A significant linear correlation was found between ONSD and ICP (r = 0.771, p < 0.0001). Enlarged ONSD was a robust predictor of elevated ICP. With an ONSD cutoff of 5.48 mm (ICP > 13 mm Hg), sensitivity and specificity were 91.1% and 88.0%, respectively; a cutoff of 5.83 mm (ICP > 22 mm Hg) yielded sensitivity and specificity of 94.4% and 81.0%, respectively. CONCLUSIONS: Ultrasonographic ONSD is strongly correlated with invasive ICP measurements and may serve as a sensitive and noninvasive method for detecting elevated ICP in TBI patients after DC.