大脑周动脉瘤血管内弹簧圈栓塞与血流导向装置治疗的回顾性队列评估
结果显示弹簧圈栓塞组复发率较高(破裂组40%、未破裂/复发组22%),而血流导向装置治疗的动脉瘤均实现100%闭塞,无再破裂或新发破裂,79%患者临床预后良好(mRS 0-2)。
要点
- 弹簧圈栓塞大脑周动脉瘤存在明确复发率,需及时血管造影监测。
- 血流导向装置治疗大脑周动脉瘤显示优异疗效,全部实现闭塞。
- 破裂组与未破裂/复发组中血流导向装置均未观察到再破裂或新发破裂。
核心结论
- 大脑周动脉瘤弹簧圈栓塞与明确复发率相关,需及时血管造影监测。
- 血流导向装置对破裂和未破裂大脑周动脉瘤均显示优异疗效。
主要发现
- 破裂组中22个动脉瘤(88%)采用弹簧圈栓塞,其余采用血流导向装置;初次血管造影随访率72%,中位随访159天。
- 总体复发率40%(10/25),中位时间376天,均发生在弹簧圈栓塞的动脉瘤中;6个复发动脉瘤再治疗(2个再次弹簧圈栓塞,4个血流导向装置)。
- 未破裂/复发组中5个动脉瘤(55%)采用弹簧圈栓塞,其余采用血流导向装置;血管造影随访率100%,中位随访267天;复发率22%(2/9),均发生在弹簧圈栓塞的动脉瘤中。
- 总体27个动脉瘤采用弹簧圈栓塞,9个采用血流导向装置,3个采用「部分」血流导向装置;所有采用Pipeline血流导向装置治疗的动脉瘤均实现100%闭塞。
- 未观察到再破裂或新发破裂;79%患者临床预后良好(改良Rankin量表0-2分)。
关键数值与推荐
- 破裂组弹簧圈栓塞比例88%(22/25),复发率40%(10/25)。
- 未破裂/复发组弹簧圈栓塞比例55%(5/9),复发率22%(2/9)。
- 血流导向装置治疗的动脉瘤100%闭塞。
- 临床预后良好(mRS 0-2)比例79%。
临床怎么用
- 对弹簧圈栓塞治疗的大脑周动脉瘤应进行及时血管造影监测以发现复发。
- 血流导向装置可作为大脑周动脉瘤的有效治疗选择,无论破裂或未破裂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The adoption of endovascular techniques for treatment of pericallosal artery aneurysms (PAAs) has been comparatively gradual due to anatomic and technological factors. We conducted a retrospective cohort study to evaluate the outcomes of PAA treatment with coiling and flow diversion at our institution. METHODS: This was a retrospective study of patients treated endovascularly for PAAs from December 2007 to January 2019. RESULTS: In total, 33 patients with 34 aneurysms were included (25 aneurysms ruptured, 9 unruptured or recurrent). Of the ruptured group, 22 were coiled (88%) and rest treated with flow diversion. Initial angiographic follow up rate was 72%, at median of 159 days. Overall recurrence rate was 40% (10/25) at median of 376 days, all among coiled aneurysms. 6 recurrent aneurysms were retreated with further coiling (2) and flow diversion (4). Of the unruptured/recurrent group, 5 were coiled (55%) and remainder treated with flow diversion. Angiographic follow-up rate was 100% at median of 267 days. Recurrence rate was 22% (2/9), both in coiled aneurysms. Overall, 27 aneurysms were coiled, 9 treated with flow diversion and 3 with "partial" flow diversion. All aneurysms treated with pipeline flow diversion achieved 100% occlusion. No re-rupture or new rupture was observed. Good clinical outcome (modified Rankin Scale 0-2) was seen in 79% of patients. CONCLUSIONS: Our study demonstrates that endovascular coiling for PAAs is associated with a definite rate of recurrence, which has to be monitored with timely angiography. We also demonstrate the excellent effectiveness of flow diversion for PAAs with either presentation.
引用
- Sattur MG, Li Y, Almallouhi E, et al. Lessons Learned from Endovascular Coil Embolization of Pericallosal Artery Aneurysms and Adoption of Flow Diversion: A Retrospective Cohort Assessment of the Efficacy of Coiling and Flow Diversion. World Neurosurg. 2019. PMID: 31150866. doi:10.1016/j.wneu.2019.05.181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。