文献速递小儿神经外科与脑积水神经重症

后入路脑室腹腔分流术的方法与装置:25年迭代优化

Methods and Devices for Posterior Ventriculoperitoneal Shunt Placement Surgery: 25 Years of Iterative Refinement.
PubMed 文献 · World Neurosurg · 2019-05-25

本文回顾单中心2007至2018年468例后入路脑室腹腔分流术,采用经25年演进的方法与定制装置,实现98.29%的脑室管最佳置入率,仅0.43%因置管位置不良出现短暂神经功能缺损,总体并发症率与既往文献相当。

要点

  • 后入路VPS在定制方法与装置辅助下,脑室管最佳置入率可达98.29%。
  • 置管位置不良相关新发神经功能缺损仅0.43%,且均为短暂性。
  • 非置管准确性相关并发症率与既往文献相比具有优势。

核心结论

  • 采用本系列描述的方法与装置,后入路VPS可安全实施并获得高度的脑室管置入准确性。

研究设计与样本

  • 单中心回顾性研究,纳入2007至2018年接受后入路VPS的468例患者,回顾病历与影像学资料,收集置管准确性数据并记录并发症。

主要发现

  • 脑室管最佳置入率为98.29%;其余1.71%中,一半(0.85%)需急性翻修手术。
  • 4例(0.85%)术后出现新发神经功能缺损,其中2例与脑实质内出血相关,2例(0.43%)由置管位置不良导致,后者所致缺损为短暂性。
  • 非置管准确性相关原因的并发症率与既往文献报告相比具有优势。

临床怎么用

  • 后入路VPS可借助本系列所述方法与简单定制装置,以提高脑室管置入准确性并降低并发症率。
  • 术后需关注置管位置不良相关的新发神经功能缺损,但此类缺损多为短暂性。

局限性

  • 本文为单中心回顾性研究,结果基于该机构特定方法与定制装置,外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The posterior ventriculoperitoneal shunt (VPS) placement procedure is technically efficient and cosmetically appealing. The main limitations of the posterior approach relate to the technical challenges associated with accurately placing the ventricular catheter. In this report, we describe methods and simple devices used for posterior VPS surgery that have evolved over a >25-year period to enhance catheter placement accuracy and reduce complication rates. OBJECTIVE: We describe the combination of methods and customized devices used at a single institution to perform posterior VPS surgery. Results are presented for the most recent 11-year epoch, along with a description of sources of technical errors and plans for further methodologic refinements. MATERIALS AND METHODS: The medical records and imaging studies of 468 patients undergoing posterior VPS, from 2007 to 2018 were reviewed. Ventricular catheter placement accuracy data were collected and complications were identified and recorded. RESULTS: Optimal ventricular catheter placement was achieved in 98.29%. Of the remaining 1.71%, one half (0.85%) required acute revision surgery. Four patients (0.85%) developed new neurologic deficits following surgery; 2 were related to intraparenchymal hemorrhages and 2 (0.43%) as a result of a misplaced catheter. The deficits resulting from poor catheter placement were transient. The complication rates due to causes other than catheter placement accuracy compared favorably with those reported previously in the literature. CONCLUSIONS: Using the methods and devices described in this series, posterior VPS operations can be performed safely with a high degree of ventricular catheter placement accuracy.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Zanaty M, Roa JA, Piscopo AJ, et al. Methods and Devices for Posterior Ventriculoperitoneal Shunt Placement Surgery: 25 Years of Iterative Refinement. World Neurosurg. 2019. PMID: 31132499. doi:10.1016/j.wneu.2019.05.148

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。