文献速递脊柱脊髓外科神经肿瘤

数字机器人外视镜Synaptive Modus V在颅脑与脊柱手术中的初步应用经验

Preliminary experience with a digital robotic exoscope in cranial and spinal surgery: a review of the Synaptive Modus V system.
PubMed 文献 · Acta Neurochir (Wien) · 2019-05-22

总体结果与手术显微镜相当,视觉质量更佳且外科医生舒适度更高,但深度感知稍差,结论认为该系统可安全用于常见脊柱手术和颅内肿瘤切除。

要点

  • Synaptive Modus V外视镜可安全用于常见脊柱手术和颅内肿瘤切除
  • 图像质量优于显微镜,但深度感知稍差
  • 临床使用前进行实验室强化训练可能有帮助

核心结论

  • Synaptive Modus V系统是安全实施常见脊柱手术和颅内肿瘤切除的工具,图像质量优于显微镜但深度感知略差。

主要发现

  • 手术包括前庭神经鞘瘤1例、颅底脑膜瘤1例、嗅沟脑膜瘤1例、小脑幕脑膜瘤1例、颈椎前路间盘切除1例、颈椎椎板切除1例、腰椎间盘突出2例。
  • 总体结果与手术显微镜相当,视觉质量更佳且外科医生舒适度更高。

临床怎么用

  • 该外视镜系统可用于常见脊柱手术和颅内肿瘤切除,但需注意其深度感知稍差。
  • 临床使用前建议在实验室进行强化训练。

局限性

  • 样本量小(8例),仅为初步经验。
  • 研究周期短(2周),未报告长期或对照数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The microscope is the standard tool for microneurosurgery worldwide. However, the reduced illumination of the surgical field with the use of a conventional microscope during surgeries of deeply located pathologies remains unaddressed. Accordingly, different exoscope systems have recently been introduced in clinical practice. Here, we report our initial experience with the digital 2-dimensional Synaptive Modus V exoscope system in spinal and cranial surgery. METHODS: During a 2-week period between 27 September to 11 October 2018, we used the Synaptive Modus V exoscope system and performed eight neurosurgical procedures including spine (n = 4) and cranial procedures (n = 4). Visual quality, depth perception, complications, switching to microscope comfort level of the surgeon, and learning curve during surgery were evaluated. RESULTS: A total of eight procedures were performed, namely, vestibular schwannoma (n = 1), skull base meningioma (n = 1), olfactory groove meningioma (n = 1), tentorial meningioma (n = 1), anterior cervical discectomy (n = 1), cervical laminectomy (n = 1), and lumbar disc herniation (n = 2). The overall results were comparable to the operative microscope with better visual quality and greater comfort for the surgeon. CONCLUSION: The Synaptive Modus V system is a safe tool to perform common spinal surgeries and intracranial tumor resection. Image quality is better than a microscope but with slightly less depth perception. Vigorous training in the laboratory may be helpful before clinical use.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Muhammad S, Lehecka M, Niemelä M, et al. Preliminary experience with a digital robotic exoscope in cranial and spinal surgery: a review of the Synaptive Modus V system. Acta Neurochir (Wien). 2019. PMID: 31119395. doi:10.1007/s00701-019-03953-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。