颅骨密度比对磁共振引导聚焦超声治疗特发性震颤疗效与安全性的影响
该研究纳入189例特发性震颤患者,按颅骨密度比(SDR)阈值0.45和0.40分组,分析MRgFUS丘脑毁损术的疗效、操作效率与安全性。结果显示不同SDR组间CRST评分改善无显著差异,SDR≥0.45组更易达到目标温度,而SDR<0.45组不良事件率更低且无严重不良事件。
要点
- SDR<0.45甚至<0.40的患者仍可有效且安全地接受MRgFUS治疗。
- SDR≥0.45时操作效率更高,更易达到54°C峰值体素温度。
- SDR<0.45组不良事件率更低,且无严重不良事件。
核心结论
- MRgFUS治疗特发性震颤在SDR<0.45和SDR<0.40的患者中均可有效且安全地实施,但SDR≥0.45时操作效率更高。
研究设计与样本
- 回顾性分析189例接受MRgFUS丘脑毁损术的特发性震颤患者,按SDR阈值0.45和0.40分组,评估疗效、操作效率与安全性。
主要发现
- 189例中53例(28%)SDR<0.45,20例(11%)SDR<0.40。
- SDR≥0.45组、0.40≤SDR<0.45组和SDR<0.40组的CRST评分改善分别为58%±24%、63%±27%和49%±28%,组间差异无统计学意义(p=0.0744)。
- SDR≥0.45组更常达到目标温度(p<0.001)。
- SDR<0.45组不良事件率更低(p=0.013),且无严重不良事件。
关键数值与推荐
- SDR分组阈值采用0.45和0.40。
- 疗效以MRgFUS术后1年CRST评分改善评估。
- 操作效率以达到54°C峰值体素温度的难易程度判定。
- 安全性以最严重操作相关不良事件的发生率评估。
临床怎么用
- 对于SDR<0.45甚至<0.40的特发性震颤患者,仍可考虑MRgFUS丘脑毁损术,但需知晓达到目标温度可能更困难。
- SDR≥0.45的患者操作效率更高,可优先预期更顺利的温度达成。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Skull density ratio (SDR) assesses the transparency of the skull to ultrasound. Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy in essential tremor (ET) patients with a lower SDR may be less effective, and the risk for complications may be increased. To address these questions, the authors analyzed clinical outcomes of MRgFUS thalamotomy based on SDRs. METHODS: In 189 patients, 3 outcomes were correlated with SDRs. Efficacy was based on improvement in Clinical Rating Scale for Tremor (CRST) scores 1 year after MRgFUS. Procedural efficiency was determined by the ease of achieving a peak voxel temperature of 54°C. Safety was based on the rate of the most severe procedure-related adverse event. SDRs were categorized at thresholds of 0.45 and 0.40, selected based on published criteria. RESULTS: Of 189 patients, 53 (28%) had an SDR < 0.45 and 20 (11%) had an SDR < 0.40. There was no significant difference in improvement in CRST scores between those with an SDR ≥ 0.45 (58% ± 24%), 0.40 ≤ SDR < 0.45 (i.e., SDR ≥ 0.40 but < 0.45) (63% ± 27%), and SDR < 0.40 (49% ± 28%; p = 0.0744). Target temperature was achieved more often in those with an SDR ≥ 0.45 (p < 0.001). Rates of adverse events were lower in the groups with an SDR < 0.45 (p = 0.013), with no severe adverse events in these groups. CONCLUSIONS: MRgFUS treatment of ET can be effectively and safely performed in patients with an SDR < 0.45 and an SDR < 0.40, although the procedure is more efficient when SDR ≥ 0.45.
引用
- D'Souza M, Chen KS, Rosenberg J, et al. Impact of skull density ratio on efficacy and safety of magnetic resonance-guided focused ultrasound treatment of essential tremor. J Neurosurg. 2019. PMID: 31026836. doi:10.3171/2019.2.JNS183517
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。