本研究为单臂前瞻性日本HydroSoft登记研究,纳入122个直径<10 mm且HydroSoft弹簧圈长度占比≥50%的动脉瘤,评估安全性和1年再通率。结果显示未发生颅内出血,2例轻微缺血性卒中,1年再通5例(4.1%),高栓塞体积比和小瘤颈与血栓形成进展显著相关。

要点

  • HydroSoft弹簧圈栓塞<10 mm动脉瘤1年再通率4.1%,安全性可接受。
  • 高栓塞体积比和小瘤颈与1年后血栓形成进展显著相关。
  • 初始造影显示体部填充的动脉瘤再通风险较高。

核心结论

  • HydroSoft弹簧圈治疗1年后的安全性和再通预防效果尚可接受。
  • 高栓塞体积比可促进随访期间瘤颈残余和体部填充动脉瘤的血栓形成进展。

研究设计与样本

  • 单臂前瞻性日本HydroSoft登记研究,纳入直径<10 mm且HydroSoft弹簧圈长度占比≥50%的动脉瘤,共122个。

主要发现

  • 平均最大直径6.4 mm,平均瘤颈3.9 mm,HydroSoft弹簧圈平均长度占比84.3%。
  • 无颅内出血发生,2例患者发生轻微缺血性卒中。
  • 术后即刻造影完全闭塞20例(16.4%)、瘤颈残余32例(26.2%)、体部填充67例(54.9%)。
  • 1年随访造影完全闭塞68例(55.7%)、瘤颈残余15例(12.3%)、体部填充15例(12.3%),再通5例(4.1%)。
  • 再通者中4例初始为体部填充、1例为瘤颈残余;另11例仍体部填充但血栓形成促进。

临床怎么用

  • 对于<10 mm颅内动脉瘤,使用HydroSoft弹簧圈栓塞时关注栓塞体积比和瘤颈大小以促进血栓形成。

局限性

  • 单臂研究,无对照组,再通相关因素分析未发现显著因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The effect of HydroSoft coils on the prevention of recanalization and thrombosis after embolization is unclear. We herein report the results of the single-armed prospective Japanese HydroSoft Registry. METHODS: Aneurysms with a diameter of <10 mm that were treated with a ≥50% length of HydroSoft coils were registered. We evaluated the safety and recanalization rate and analyzed the factors related to their recanalization and thrombosis 1 year later. RESULTS: In total, 122 aneurysms were registered. Their mean maximum diameter and neck length were 6.4 and 3.9 mm, respectively. The mean length of the HydroSoft coils was 84.3%. No intracranial hemorrhage occurred, but 2 patients developed minor ischemic strokes. Angiographic examination immediately after the procedure showed complete obliteration, neck remnant (NR), and body filling (BF) in 20 (16.4%), 32 (26.2%), and 67 (54.9%) cases, respectively. One-year follow-up angiography showed complete obliteration, NR, and BF in 68 (55.7%), 15 (12.3%), and 15 (12.3%) cases, respectively, and 5 aneurysms (4.1%) were recanalized (4 and 1 with BF and NR as their initial angiographic result, respectively). Another 11 aneurysms still showed BF, although their thrombosis was promoted. No significant factors related to recanalization were identified. A high volume embolization ratio and small neck were significantly associated with thrombosis 1 year after embolization with HydroSoft coils. CONCLUSIONS: The safety and prevention of recanalization 1 year after the treatment appeared acceptable. The high volume embolization ratio associated with HydroSoft coils could induce progression of thrombosis for aneurysms characterized by NR and BF during the follow-up period.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Imamura H, Sakai N, Ito Y, et al. Prospective Registry of Embolization of Intracranial Aneurysms Using HydroSoft Coils: Results of the Japanese HydroSoft Registry. World Neurosurg. 2019. PMID: 30947007. doi:10.1016/j.wneu.2019.03.234

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。