文献速递脑血管病外科

基于定量DSA的静脉淤滞指数与幕上动静脉畸形出血相关

Stasis index from hemodynamic analysis using quantitative DSA correlates with hemorrhage of supratentorial arteriovenous malformation: a cross-sectional study.
PubMed 文献 · J Neurosurg · 2019-04-26

该横断面研究回顾2011–2017年119例接受DSA和MRI的成人幕上AVM患者,用QDSA计算引流静脉淤滞指数并与传统DSA血管构筑分析比较。调整年龄、性别和畸形团体积后,唯一深静脉引流(p<0.01)和最主要引流静脉淤滞指数(p=0.02)为出血独立危险因素;两种方法ROC曲线下面积相似(0.75 vs 0.73)。

要点

  • 唯一深静脉引流与最主要引流静脉淤滞指数是幕上AVM出血的独立危险因素
  • 淤滞指数>2.18鉴别出血组敏感度52.6%、特异度81.5%
  • QDSA与传统DSA血管构筑分析对AVM出血风险评估效能相当

核心结论

  • QDSA测得的最主要引流静脉淤滞指数较高是与幕上AVM破裂相关的客观预警标志。
  • QDSA与传统DSA血管构筑分析对AVM出血风险评估效能相当。
  • 建议AVM出血风险评估联合DSA血管构筑与QDSA分析。

研究设计与样本

  • 横断面研究,回顾性纳入2011–2017年接受DSA和MRI的成人幕上AVM患者119例。
  • 采用单因素和多因素logistic回归分析血管构筑、DSA参数、年龄、性别及畸形团体积。
  • 用QDSA软件分析DSA图像,淤滞指数定义为流入梯度除以流出梯度绝对值。
  • 用ROC曲线比较传统DSA血管构筑分析与QDSA血流动力学参数的诊断效能。

主要发现

  • 调整年龄、性别和畸形团体积后,唯一深静脉引流为出血独立危险因素(p<0.01)。
  • 调整后最主要引流静脉淤滞指数亦为出血独立危险因素(p=0.02)。
  • 传统DSA方法ROC曲线下面积为0.75,QDSA血流动力学分析为0.73,两者相似。
  • 静脉淤滞指数>2.18鉴别出血组敏感度52.6%、特异度81.5%。

关键数值与推荐

  • 淤滞指数定义为流入梯度除以流出梯度绝对值。
  • 静脉淤滞指数>2.18作为鉴别出血组的阈值,敏感度52.6%、特异度81.5%。
  • 唯一深静脉引流与最主要引流静脉淤滞指数为出血独立危险因素(p<0.01与p=0.02)。

临床怎么用

  • 对幕上AVM患者可联合传统DSA血管构筑与QDSA淤滞指数进行出血风险综合评估。
  • 关注唯一深静脉引流及最主要引流静脉淤滞指数升高的患者。
  • QDSA为无额外辐射和对比剂的补充性无创方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Assessments of hemorrhage risk based on angioarchitecture have yielded inconsistent results, and quantitative hemodynamic studies have been limited to small numbers of patients. The authors examined whether cerebral hemodynamic analysis using quantitative digital subtraction angiography (QDSA) can outperform conventional DSA angioarchitecture analysis in evaluating the risk of hemorrhage associated with supratentorial arteriovenous malformations (AVMs). METHODS: A cross-sectional study was performed by retrospectively reviewing adult supratentorial AVM patients who had undergone both DSA and MRI studies between 2011 and 2017. Angioarchitecture characteristics, DSA parameters, age, sex, and nidus volume were analyzed using univariate and multivariate logistic regression, and QDSA software analysis was performed on DSA images. Based on the QDSA analysis, a stasis index, defined as the inflow gradient divided by the absolute value of the outflow gradient, was determined. The receiver operating characteristic (ROC) curve was used to compare diagnostic performances of conventional DSA angioarchitecture analysis and analysis using hemodynamic parameters based on QDSA. RESULTS: A total of 119 supratentorial AVM patients were included. After adjustment for age at diagnosis, sex, and nidus volume, the exclusive deep venous drainage (p < 0.01), observed through conventional angioarchitecture examination using DSA, and the stasis index of the most dominant drainage vein (p = 0.02), measured with QDSA hemodynamic analysis, were independent risk factors for hemorrhage. The areas under the ROC curves for the conventional DSA method (0.75) and QDSA hemodynamics analysis (0.73) were similar. A venous stasis index greater than 2.18 discriminated the hemorrhage group with a sensitivity of 52.6% and a specificity of 81.5%. CONCLUSIONS: In QDSA, a higher stasis index of the most dominant drainage vein is an objective warning sign associated with supratentorial AVM rupture. Risk assessments of AVMs using QDSA and conventional DSA angioarchitecture were equivalent. Because QDSA is a complementary noninvasive approach without extra radiation or contrast media, comprehensive hemorrhagic risk assessment of cerebral AVMs should include both DSA angioarchitecture and QDSA analyses.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lin TM, Yang HC, Lee CC, et al. Stasis index from hemodynamic analysis using quantitative DSA correlates with hemorrhage of supratentorial arteriovenous malformation: a cross-sectional study. J Neurosurg. 2019. PMID: 31026828. doi:10.3171/2019.1.JNS183386

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。