文献速递神经重症脑血管病外科

手术野血液增加小鼠模型皮层扩散性去极化频率

Cortical spreading depolarizations induced by surgical field blood in a mouse model of neurosurgery.
PubMed 文献 · J Neurosurg · 2019-04-05

研究采用表达GCaMP6f的小鼠神经外科模型,通过共聚焦显微镜监测皮层扩散性去极化(CSD)。电凝可诱发CSD,手术野血液使自发性CSD频率显著增加(1.35±0.37 vs 0.13±0.16次/小时,p=0.002)。氯胺酮可降低自发性及电凝诱发的CSD频率。

要点

  • 电凝可诱发CSD,平均每次电凝产生0.67±0.08次CSD事件。
  • 手术野血液使自发性CSD频率显著增加(1.35±0.37 vs 0.13±0.16次/小时,p=0.002)。

核心结论

  • 监测神经元GCaMP6f信号比监测IOS更灵敏、更保真地检测CSD波。
  • 电凝可靠地诱发CSD波,皮层表面应用血液增加自发性CSD频率。
  • 氯胺酮可阻断刺激性和自发性CSD。

研究设计与样本

  • 小鼠神经外科模型,使用CamKII阳性神经元表达GCaMP6f的小鼠,通过共聚焦显微镜检测皮层表面荧光增加来监测CSD波。
  • 通过相邻钻孔对皮层表面进行电凝,并通过同一钻孔将尾静脉血滴到脑表面模拟手术野血液。

主要发现

  • 电凝诱发CSD,平均每次电凝产生0.67±0.08次CSD事件,重复电凝可诱导多个CSD波(平均7.9±1.3次,单只动物最多13次)。
  • 手术野血液存在时自发性CSD显著增加(1.35±0.37 vs 0.13±0.16次/小时,p=0.002)。
  • 氯胺酮降低自发性CSD频率(1.35±0.37降至0.36±0.15次/小时,p=0.016)和电凝刺激的CSD频率(0.80±0.05降至0.18±0.08次/电凝,p=0.00002)。

关键数值与推荐

  • 电凝平均每次产生0.67±0.08次CSD事件。
  • 手术野血液使自发性CSD频率为1.35±0.37次/小时 vs 无血液时0.13±0.16次/小时(p=0.002)。
  • 氯胺酮使自发性CSD频率从1.35±0.37降至0.36±0.15次/小时(p=0.016)。
  • 氯胺酮使电凝刺激的CSD频率从0.80±0.05降至0.18±0.08次/电凝(p=0.00002)。

临床怎么用

  • GCaMP6f荧光监测可更灵敏地检测CSD事件。
  • 电凝和手术野血液是术中CSD的诱发因素。
  • 氯胺酮可降低自发性及电凝诱发的CSD频率。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Cortical spreading depolarization (CSD) has been linked to poor clinical outcomes in the setting of traumatic brain injury, malignant stroke, and subarachnoid hemorrhage. There is evidence that electrocautery during neurosurgical procedures can also evoke CSD waves in the brain. It is unknown whether blood contacting the cortical surface during surgical bleeding affects the frequency of spontaneous or surgery-induced CSDs. Using a mouse neurosurgical model, the authors tested the hypothesis that electrocautery can induce CSD waves and that surgical field blood (SFB) is associated with more CSDs. The authors also investigated whether CSD can be reliably observed by monitoring the fluorescence of GCaMP6f expressed in neurons. METHODS: CSD waves were monitored by using confocal microscopy to detect fluorescence increases at the cortical surface in mice expressing GCaMP6f in CamKII-positive neurons. The cortical surface was electrocauterized through an adjacent burr hole. SFB was simulated by applying a drop of tail vein blood to the brain through the same burr hole. RESULTS: CSD waves were readily detected in GCaMP6f-expressing mice. Monitoring GCaMP6f fluorescence provided far better sensitivity and spatial resolution than detecting CSD events by observing changes in the intrinsic optical signal (IOS). Forty-nine percent of the CSD waves identified by GCaMP6f had no corresponding IOS signal. Electrocautery evoked CSD waves. On average, 0.67 ± 0.08 CSD events were generated per electrocautery episode, and multiple CSD waves could be induced in the same mouse by repeated cauterization (average, 7.9 ± 1.3 events; maximum number in 1 animal, 13 events). In the presence of SFB, significantly more spontaneous CSDs were generated (1.35 ± 0.37 vs 0.13 ± 0.16 events per hour, p = 0.002). Ketamine effectively decreased the frequency of spontaneous CSD waves (1.35 ± 0.37 to 0.36 ± 0.15 CSD waves per hour, p = 0.016) and electrocautery-stimulated CSD waves (0.80 ± 0.05 to 0.18 ± 0.08 CSD waves per electrocautery, p = 0.00002). CONCLUSIONS: CSD waves are detected with far greater sensitivity and fidelity by monitoring GCaMP6f signals in neurons than by monitoring IOSs. Electrocautery reliably evokes CSD waves, and the frequency of spontaneous CSD waves is increased when blood is applied to the cortical surface. These experimental conditions recapitulate common scenarios in the neurosurgical operating room. Ketamine, a clinically available pharmaceutical agent, can block stimulated and spontaneous CSDs. More research is required to understand the clinical importance of intraoperative CSD.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Srienc AI, Chiang PP, Schmitt AJ, et al. Cortical spreading depolarizations induced by surgical field blood in a mouse model of neurosurgery. J Neurosurg. 2019. PMID: 30952117. doi:10.3171/2018.12.JNS181130

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。