文献速递脑血管病外科神经重症

血管内超声辅助支架置入治疗脑静脉窦狭窄所致特发性颅内高压的安全性和有效性:一项初步研究

Safety and efficacy of intravascular ultrasound as an adjunct to stenting for cerebral venous sinus stenosis-induced idiopathic intracranial hypertension: a pilot study.
PubMed 文献 · J Neurosurg · 2019-03-01

该回顾性研究分析了12例特发性颅内高压(IIH)患者(9例非血栓性脑静脉窦狭窄,3例继发性狭窄合并脑静脉窦血栓形成),在静脉成形术中应用血管内超声(IVUS)辅助诊断和支架置入。IVUS图像对狭窄诊断优良,清晰显示3例(25%)管腔内血栓、1例(8.3%)巨大蛛网膜颗粒、2例(16.7%)静脉内分隔或间隔及6例(50%)血管壁增厚。1年随访时12例中10例临床症状消失。结论认为IVUS是有前景的工具,可能提高IIH诊断准确性,有助于识别颅内静脉狭窄类型、辅助支架选择和引导支架置入,值得进一步研究。

要点

  • IVUS辅助静脉窦支架置入在12例IIH患者中无技术或神经并发症。
  • IVUS清晰显示管腔内血栓3例(25%)、巨大蛛网膜颗粒1例(8.3%)。
  • 1年随访12例中10例临床症状消失。

核心结论

  • IVUS是有前景的工具,可能提高IIH诊断准确性,有助于识别颅内静脉狭窄类型、辅助支架选择和引导支架置入,值得进一步研究。

研究设计与样本

  • 回顾性分析前瞻性数据库,纳入2016年4月至2017年2月接受IVUS引导静脉窦支架置入的12例IIH患者(9例非血栓性CVSS,3例继发性狭窄合并CVST)。

主要发现

  • IVUS清晰显示管腔内血栓3例(25%)、巨大蛛网膜颗粒1例(8.3%)、静脉内分隔或间隔2例(16.7%)、血管壁增厚6例(50%)。
  • 1年随访时12例中10例临床症状消失。

临床怎么用

  • IVUS可作为静脉窦支架置入的辅助工具,用于诊断狭窄、识别狭窄类型、辅助支架选择和引导支架置入。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Symptomatic intracranial hypertension can be caused by cerebral venous sinus stenosis (CVSS) and cerebral venous sinus thrombotic (CVST) stenosis, which is usually found in some patients with idiopathic intracranial hypertension (IIH). Recently, at the authors' center, they utilized intravascular ultrasound (IVUS) as an adjunct to conventional venoplasty or stenting to facilitate diagnosis and accurate stent placement in CVSS. METHODS: The authors designed a retrospective review of their prospective database of patients who underwent IVUS-guided venous sinus stenting between April 2016 and February 2017. Clinical, radiological, and ophthalmological information was recorded and analyzed. IVUS was performed in 12 patients with IIH (9 with nonthrombotic CVSS, 3 with secondary stenosis combined with CVST) during venoplasty through venous access. The IVUS catheter was used from a proximal location to the site of stenosis. Post-stenting follow-up, including symptomatic improvement, stent patency, and adjacent-site stenosis, was assessed at 1 year. RESULTS: Thirteen stenotic cerebral sinuses in 12 patients were corrected using IVUS-guided stenting. No technical or neurological complications were encountered. The IVUS images were excellent for the diagnosis of the stenosis, and intraluminal thrombi were clearly visualized by using IVUS in 3 (25%) of the 12 patients. A giant arachnoid granulation was demonstrated in 1 (8.3%) of the 12 patients. Intravenous compartments or septations (2 of 12, 16.7%) and vessel wall thickening (6 of 12, 50%) were also noted. At 1-year follow-up, 10 of 12 patients were clinically symptom-free in our series. CONCLUSIONS: IVUS is a promising tool with the potential to improve the diagnostic accuracy in IIH, aiding in identification of the types of intracranial venous stenosis, assisting in stent selection, and guiding stent placement. Further study of the utility of IVUS in venous stenting and venous stenosis pathology is warranted.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Yan F, Rajah G, Ding Y, et al. Safety and efficacy of intravascular ultrasound as an adjunct to stenting for cerebral venous sinus stenosis-induced idiopathic intracranial hypertension: a pilot study. J Neurosurg. 2019. PMID: 30835685. doi:10.3171/2018.11.JNS181885

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。