文献速递神经肿瘤

基于增强MRI影像组学的脑膜瘤亚型鉴别研究

Differentiation Researches on the Meningioma Subtypes by Radiomics from Contrast-Enhanced Magnetic Resonance Imaging: A Preliminary Study.
PubMed 文献 · World Neurosurg · 2019-03-01

本研究随机选取241例脑膜瘤患者(脑膜内皮型80例、纤维型80例、过渡型81例),从术前增强T1加权图像提取385个影像组学特征,经预处理后采用Fisher判别分析建模,并用留一交叉验证评估。模型对四组鉴别准确率分别为99.4%、98.8%、100%和100%,留一交叉验证准确率分别为91.3%、95.0%、100%和94.2%。结论认为影像组学特征结合Fisher判别分析在脑膜瘤亚型术前鉴别中表现满意,具有临床应用潜力。

要点

  • 增强T1加权图像可提取385个影像组学特征用于脑膜瘤亚型鉴别。
  • Fisher判别分析模型对四组鉴别的准确率在98.8%至100%之间。
  • 留一交叉验证准确率在91.3%至100%之间,支持模型稳定性。

核心结论

  • 影像组学特征结合Fisher判别分析在脑膜瘤亚型术前鉴别中表现满意,具有临床应用潜力。

研究设计与样本

  • 随机选取241例接受肿瘤切除的脑膜瘤患者,包括脑膜内皮型80例、纤维型80例、过渡型81例。
  • 所有患者使用同一台磁共振扫描仪(GE 3.0 T)检查,术前增强T1加权图像可用。
  • 由2名经验丰富的放射学专家评估241例患者的增强T1加权图像影像组学特征。
  • 将脑膜瘤分为4组:脑膜内皮型 vs 纤维型(组1)、纤维型 vs 过渡型(组2)、脑膜内皮型 vs 过渡型(组3)、脑膜内皮型 vs 纤维型 vs 过渡型(组4)。

主要发现

  • 从每例患者图像中提取385个影像组学特征。
  • 采用Fisher判别分析前应用多种预处理方法降低冗余并突出不同脑膜瘤间差异。
  • Fisher判别分析模型对组1、2、3、4的鉴别准确率分别为99.4%、98.8%、100%和100%。
  • 留一交叉验证法对组1、2、3、4的准确率分别为91.3%、95.0%、100%和94.2%。

关键数值与推荐

  • Fisher判别分析模型鉴别准确率:组1为99.4%,组2为98.8%,组3为100%,组4为100%。
  • 留一交叉验证准确率:组1为91.3%,组2为95.0%,组3为100%,组4为94.2%。

临床怎么用

  • 影像组学特征结合Fisher判别分析可用于脑膜瘤亚型的术前鉴别诊断。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Meningioma subtypes are one of the most common key points to the treatment and prognosis of patients. The purpose of this study was to investigate the differential diagnostic value of radiomics features on meningioma. METHODS: A total of 241 patients with meningioma who had undergone tumor resection were randomly selected including 80 with meningothelial meningioma, 80 with fibrous meningioma, and 81 with transitional meningioma. These meningiomas were divided into 4 groups including: meningothelial versus fibrous (group 1), fibrous versus transitional (group 2), meningothelial versus transitional (group 3), and meningothelial versus fibrous versus transitional (group 4). All patients were examined using the same magnetic resonance scanner (GE 3.0 T) and the preoperative contrast-enhanced T1-weighted images were available. Radiomics features from the contrast-enhanced T1-weighted images of 241 patients were evaluated by 2 experienced radiology specialists. RESULTS: A total of 385 radiomics features were extracted from the images of each patient. Several preprocessing methods were applied on the radiomics dataset to reduce the redundancy and highlight differences between different meningioma before the Fisher discrimination analysis was adopted and leave one out cross validation methods were used for the model validation. The differentiation accuracies of the Fisher discriminant analysis model for groups 1, 2, 3, and 4 were 99.4%, 98.8%, 100% and 100%, respectively; leave one out cross validation method was achieved for group 1, 2, 3, and 4 with the accuracies of 91.3%, 95.0%, 100%, and 94.2%, respectively. CONCLUSIONS: Radiomics features and the combined Fisher discriminant analysis could provide satisfactory performance in the preoperative differential diagnosis of meningioma subtypes and enable the potential ability for clinical application.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Niu L, Zhou X, Duan C, et al. Differentiation Researches on the Meningioma Subtypes by Radiomics from Contrast-Enhanced Magnetic Resonance Imaging: A Preliminary Study. World Neurosurg. 2019. PMID: 30831287. doi:10.1016/j.wneu.2019.02.109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。