文献速递神经肿瘤小儿神经外科与脑积水

CUSA 标本在儿童脑肿瘤细胞悬液细胞计量分析中的应用

Cytometric analysis of cell suspension generated by cavitron ultrasonic surgical aspirator in pediatric brain tumors.
PubMed 文献 · J Neurooncol · 2019-03-02

本研究评估了儿童脑肿瘤手术中 CUSA 获取的标本用于流式与质谱细胞计数的可行性,19 例样本中 16 例细胞活率低于 50%,质谱面板中加入顺铂可筛选活细胞,肿瘤细胞中非活细胞比例高于白细胞。

要点

  • CUSA 标本可制备细胞悬液用于流式和质谱细胞计数分析。
  • 19 例儿童脑肿瘤 CUSA 标本中 16 例细胞活率低于 50%。
  • 质谱面板直接加入顺铂活率标记可仅选活细胞分析。

核心结论

  • 使用活率标记进行肿瘤细胞免疫表型分析时,所研究标记的表达可被评估。
  • 适合的标记可通过质谱细胞计数等高通量方法筛选,诊断相关标记可用流式细胞计数研究。

研究设计与样本

  • 研究纳入 19 例儿童脑肿瘤患者的 CUSA 标本,制备细胞悬液后行流式和质谱细胞计数分析。

主要发现

  • 19 例中 16 例获取样本的细胞活率低于 50%。
  • 质谱细胞计数分析可区分脑肿瘤细胞与污染白细胞,后者比例在各标本间不同。
  • 质谱面板中加入顺铂活率标记可选择活细胞进行后续分析。
  • 肿瘤细胞中非活细胞比例高于白细胞。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was to test the possibility of using specimens obtained by a cavitron ultrasonic surgical aspirator (CUSA) in flow and mass cytometry investigations of pediatric brain tumors. METHODS: CUSA specimens obtained from 19 pediatric patients with brain tumors were investigated. Flow and mass cytometry methods were applied to analyze the composition of material collected using the CUSA. Cell suspensions were prepared from CUSA aspirates. Then sample viability was assessed by conventional flow cytometry and subsequently stained with a panel of 31 metal-labeled antibodies. RESULTS: Viability assessment was performed using conventional flow cytometry. Viability of cells in the acquired samples was below 50% in 16 of 19 cases. A mass cytometry investigation and subsequent analysis enabled us to discriminate brain tumor cells from contaminating leukocytes, whose proportions varied across the specimens. The addition of the viability marker cisplatin directly into the mass cytometry panel gave the means to selecting viable cells only for subsequent analyses. The proportion of non-viable cells was higher among tumor cells compared leukocytes. CONCLUSIONS: When the analysis of the tumor cell immunophenotype is performed with markers for determining viability, the expression of the investigated markers can be evaluated. Suitable markers can be selected by high-throughput methods, such as mass cytometry, and those that are diagnostically relevant can be investigated using flow cytometry, which is more flexible in terms of time.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Vaskova M, Tichy M, Zamecnik J, et al. Cytometric analysis of cell suspension generated by cavitron ultrasonic surgical aspirator in pediatric brain tumors. J Neurooncol. 2019. PMID: 30827009. doi:10.1007/s11060-019-03135-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。