泰国脑室外引流管理实践:EPRACT研究结果
该调查基于泰国101家医院中58家的反馈,描述脑室外引流(EVD)的置入、维护、质量改进(QI)实践及感染发生率。结果显示多数医院年EVD量≤100例、使用非抗菌导管、每日预防性使用抗生素且无书面操作规范,仅少数监测颅内压,EVD感染率多≤5%。作者提出亟需建立EVD相关QI流程、可靠追踪感染率并制定标准化方案。
要点
- 75.9%的医院年EVD置入量≤100例,98.3%使用非抗菌导管,62.1%每日预防性使用抗生素。
- 77.6%的医院在院内转运期间不监测颅内压,94.8%无书面EVD置入与维护规范。
- 69%的医院将EVD感染作为QI指标追踪,但多达三分之一的医院未追踪任何EVD QI指标。
核心结论
- 该研究识别了泰国EVD管理中的质量改进机会,作者认为亟需建立EVD相关QI流程、可靠追踪EVD感染率、参照美国指南制定标准化EVD方案,并在中低收入国家 examining EVD实践与临床结局的关联。
研究设计与样本
- 基于问卷调查的研究,联系101家医院,58家医院回复(回复率57.4%),其中≥600张床位的医院占44.8%,设有神经重症监护单元的医院占53%。
主要发现
- EVD置入原因包括动脉瘤性蛛网膜下腔出血、创伤性脑损伤及脑室腹腔分流故障或感染;75.9%的医院年EVD管理量≤100例。
- 98.3%的医院使用非抗菌EVD导管,56.9%的医院不常规进行脑脊液采样,62.1%的医院每日预防性使用抗生素。
- 77.6%的医院在院内转运期间不监测颅内压;69%的医院将EVD感染作为常规追踪的QI指标,但多达三分之一的医院未追踪任何EVD QI指标。
- 94.8%的医院无书面EVD置入与维护规范;79.3%的医院报告上一年EVD感染率≤5%。
- 作者认为低EVD感染率、高成本和/或设备缺乏可解释抗菌导管和颅内压监测使用率低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We explored the external ventricular drain (EVD) practices in Thailand. METHODS: We performed a survey-based study to describe EVD insertion, maintenance, quality improvement (QI) practices, and incidence of EVD infection. RESULTS: The study included 58 of 101 hospitals contacted (57.4% response rate), with ≥600 beds (44.8%) and dedicated neurocritical care units (53%). The reasons for EVD placement included aneurysmal subarachnoid hemorrhage, traumatic brain injury, and ventriculoperitoneal shunt malfunction or infection; 75.9% of the hospitals cared for ≤100 EVDs annually. In Thailand, nonantimicrobial EVD catheters (98.3%) were used most often. Most hospitals (56.9%) did not routinely sample the cerebrospinal fluid. Prophylactic daily antibiotic use was prevalent (62.1%). Most hospitals (77.6%) did not measure the intracranial pressure during intrahospital transport. EVD infection was a commonly (69%) tracked QI measure; however, up to one third of the hospitals did not track any EVD QI measure. Most hospitals (94.8%) had no written EVD insertion and maintenance protocols. Most hospitals (79.3%) reported an EVD infection rate of ≤5% in the previous year. The low EVD infection rate, high cost, and/or the lack of equipment could account for the low usage of antimicrobial catheters and intracranial pressure monitoring. CONCLUSIONS: The results of the present study have identified QI opportunities in EVD management in Thailand. The development of an EVD-related QI process, reliable tracking of EVD infection rates, adaptation of U.S. guidelines to create standardized EVD protocols, and examination of the association between EVD practices and clinical outcomes in low-to middle-income countries are urgently needed.
引用
- Alunpipatthanachai B, Thirapattaraphan P, Fried H, et al. External Ventricular Drain Management Practices in Thailand: Results of the EPRACT Study. World Neurosurg. 2019. PMID: 30851470. doi:10.1016/j.wneu.2019.02.144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。