文献速递功能神经外科

单侧丘脑脑深部电刺激与聚焦超声丘脑毁损术治疗特发性震颤的比较

Unilateral Thalamic Deep Brain Stimulation Versus Focused Ultrasound Thalamotomy for Essential Tremor.
PubMed 文献 · World Neurosurg · 2019-02-19

该研究比较了两项分别评估单侧丘脑脑深部电刺激(DBS)与磁共振引导聚焦超声(MRgFUS)丘脑毁损术治疗药物难治性特发性震颤的对照试验。两种治疗均能显著且持续1年改善震颤和生活质量,主要区别在于不良事件谱:MRgFUS组持续性神经性不良事件率更高,DBS组手术及硬件相关不良事件(包括颅内出血)率更高。作者认为需在匹配临床人群中进一步头对头比较。

要点

  • DBS和MRgFUS均显著改善药物难治性特发性震颤患者的震颤控制和生活质量,疗效持续至治疗后1年。
  • MRgFUS组持续性神经性不良事件率更高,DBS组手术及硬件相关不良事件率更高,包括颅内出血。
  • 两种方法主要通过不良事件谱区分,需匹配人群的头对头比较以更准确评估疗效和长期结局。

核心结论

  • 结合既往文献,DBS和MRgFUS均显著改善震颤控制和生活质量,两种方法主要通过不良事件谱区分。
  • 需在匹配临床人群中进行额外头对头比较,以更准确比较临床疗效和长期结局。

研究设计与样本

  • 比较两项评估DBS和MRgFUS用于单侧治疗难治性特发性震颤的对照试验。
  • 提取的临床结局包括治疗侧上肢姿势性震颤评分、生活质量(QoL)和不良事件(AE)发生率。

主要发现

  • 两项研究的基线患者特征具有可比性,但DBS患者更年轻且基线震颤更严重。
  • DBS和MRgFUS治疗的患者均有显著震颤改善,并持续至治疗后1年,生活质量也有显著改善。
  • MRgFUS队列持续性神经性不良事件率更高,而DBS组手术和硬件相关不良事件率更高,包括颅内出血。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The predominant neurosurgical approach to medication-refractory essential tremor is thalamic deep brain stimulation (DBS). The emergence of magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy has reawakened the debate surrounding the use of DBS versus thalamotomy for this indication. Herein, we aimed to provide a contemporary comparison between DBS and MRgFUS. METHODS: Two controlled trials that evaluated DBS and MRgFUS for the unilateral treatment of refractory essential tremor were compared. Clinical outcomes extracted included postural tremor score in the treated upper extremity, quality of life (QoL), and incidence of adverse events (AE). RESULTS: Baseline patient characteristics were comparable in the 2 studies, except that DBS patients were younger and had more severe baseline tremor. Both DBS- and MRgFUS-treated patients had significant tremor improvement that was sustained for 1-year posttreatment, and significant improvement in QoL. The MRgFUS cohort had higher rates of persistent neurologic AE, whereas the DBS group had higher rates of surgery- and hardware-related AEs, including intracranial hemorrhage. CONCLUSIONS: In context of prior literature, both DBS and MRgFUS significantly improve tremor control and QoL. The 2 approaches are predominantly differentiated by their AE-profile. Additional head-to-head comparison on matched clinical populations are required to more accurately compare clinical efficacy and long-term outcomes.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Harary M, Segar DJ, Hayes MT, et al. Unilateral Thalamic Deep Brain Stimulation Versus Focused Ultrasound Thalamotomy for Essential Tremor. World Neurosurg. 2019. PMID: 30794976. doi:10.1016/j.wneu.2019.01.281

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。