磁共振成像对脊髓非室管膜胶质瘤的分级分层
本研究纳入41例初诊脊髓非室管膜胶质瘤患者,术前常规MRI后1周手术并组织学分级。低级别组T2WI信噪比显著高于高级别组(165.0±108.7 vs. 98.6±44.4,P=0.016),边缘清晰者比例更高(54.5% vs. 5.3%,P=0.001);1/SNR与边缘联合的AUC为0.845(95%CI 0.717-0.973)。结论认为T2WI信号强度与边缘特征有助于分级分层。
要点
- 低级别脊髓非室管膜胶质瘤T2WI信噪比显著高于高级别组。
- 低级别组边缘清晰比例显著高于高级别组(54.5% vs. 5.3%)。
- 1/SNR与边缘联合的AUC为0.845,高于单一指标。
核心结论
- T2WI上的信号强度特征与边缘特征对脊髓非室管膜胶质瘤的分级分层有价值。
研究设计与样本
- 本研究为单中心研究,纳入41例初诊脊髓非室管膜胶质瘤患者(平均年龄29.9±16.8岁,男性27例),术前接受常规MRI(T1WI、T2WI、增强T1WI),MRI后1周手术并经组织学分为低级别与高级别组,比较两组MRI特征。
主要发现
- 低级别组T2WI信噪比显著高于高级别组(165.0±108.7 vs. 98.6±44.4;Mann-Whitney U检验P=0.016)。
- 低级别组边缘清晰者比例显著高于高级别组(54.5% vs. 5.3%;P=0.001)。
- 1/SNR的AUC为0.722(95%CI 0.564-0.880),边缘的AUC为0.736(95%CI 0.578-0.894),两者联合的AUC为0.845(95%CI 0.717-0.973)。
- 异质性、水肿、强化程度、强化信噪比、大小、纵向位置、囊肿、出血及髓内位置在低级别与高级别组间均无显著差异(均P>0.05)。
关键数值与推荐
- 低级别组T2WI信噪比165.0±108.7 vs. 高级别组98.6±44.4(P=0.016)。
- 低级别组边缘清晰比例54.5% vs. 高级别组5.3%(P=0.001)。
- 1/SNR的AUC 0.722(95%CI 0.564-0.880)。
- 边缘的AUC 0.736(95%CI 0.578-0.894)。
- 1/SNR与边缘联合的AUC 0.845(95%CI 0.717-0.973)。
临床怎么用
- 原文结论认为T2WI信号强度与边缘特征有助于脊髓非室管膜胶质瘤的分级分层,未据此给出具体临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The purpose of this study was to demonstrate the usefulness of conventional magnetic resonance imaging (MRI) in stratification of spinal cord non-ependymal gliomas. METHODS: Forty-one patients (mean age, 29.9 ± 16.8 years; 27 men) with first-diagnosed spinal cord non-ependymal gliomas underwent conventional MRI including T1-weighted, T2-weighted (T2W) and contrast-enhanced T1-weighted imaging sequences. The tumors were removed by surgery and processed by histology 1 week after MRI. Patients were divided into low-grade and high-grade groups according to histological findings. The MRI features of gliomas including signal-to-noise-ratio (SNR), margins, heterogeneity, edema, enhancement, tumor size, longitudinal location, and presence of syrinx were measured and compared between low-grade and high-grade groups using the χ2 test and the Mann-Whitney U test. RESULTS: The SNR of low-grade gliomas on T2W images was significantly higher than that of high-grade gliomas (165.0 ± 108.7 vs. 98.6 ± 44.4; P = 0.016 by the Mann-Whitney U test). The margins of low-grade gliomas were found to be clearer compared to that of high-grade gliomas (54.5% vs. 5.3%; P = 0.001). Receiver-operating-characteristic analysis revealed that the area under the curve of 1/SNR, margin and the combination of 1/SNR and margin was 0.722 (95% confidence interval [CI], 0.564-0.880), 0.736 (95% CI, 0.578-0.894), and 0.845 (95% CI, 0.717-0.973), respectively. No significant differences were found in the heterogeneity, edema, enhancement level, enhancement SNR, size, longitudinal location, cyst, hemorrhage, and intramedullary location between low-grade and high-grade non-ependymal gliomas (all P > 0.05). CONCLUSIONS: The characteristics of signal intensity and margin on T2W imaging are valuable in stratification of spinal cord non-ependymal gliomas.
引用
- Zhao B, Zhang C, Zhao X, et al. Stratification of Grade of Spinal Cord Non-Ependymal Gliomas by Magnetic Resonance Imaging. World Neurosurg. 2019. PMID: 30743029. doi:10.1016/j.wneu.2019.01.205
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。