超高场MRI颅外变形对神经外科影像导航的影响
该研究对比5例有皮肤标记物和5例无标记物患者的7-T与3-T MRI,发现颅内影像一致性极好,但颅外皮肤移位平均最大达6.8±2.0 mm(A组)和5.2±0.9 mm(B组),标记物位置平均最大差异5.6±3.1 mm。作者建议在常规CT或3-T MRI上进行患者-影像配准,再将7-T图像融合至导航设备。
要点
- 7-T MRI颅内图像与3-T MRI对应良好,未见可见的颅内变形。
- 颅外皮肤移位平均最大6.8±2.0 mm(A组)和5.2±0.9 mm(B组)。
- 皮肤标记物位置平均最大差异5.6±3.1 mm(B组)。
核心结论
- 磁化准备T1加权7-T MRI颅脑图像未见可见的颅内变形,但存在相当大的颅外移位,使7-T图像用于患者-影像配准不可靠。
- 作者建议在常规CT或3-T磁共振图像上进行患者-影像配准,随后在影像导航设备上将7-T磁共振图像与常规图像融合,直至该问题解决。
研究设计与样本
- 研究纳入5例有皮肤粘附标记物的患者和5例无标记物的患者,均接受磁化准备T1加权7-T MRI和标准3-T MRI扫描。
- 7-T与3-T图像进行刚性配准后比较,颅内变形定性评估,皮肤表面移位和皮肤粘附标记物中心位置移位定量测量。
- 另报告1例超高场影像导航颅底脑膜瘤切除术的示例病例。
主要发现
- 3-T与7-T MRI扫描之间颅内对应性极好。
- 平均最大皮肤移位在A组为6.8±2.0 mm,在B组为5.2±0.9 mm。
- 皮肤粘附标记物位置的平均最大差异在B组为5.6±3.1 mm。
- 在肿瘤切除病例中,借助7-T影像导航可早期针对脑膜瘤的血供,使后续肿瘤切除变得直接。
临床怎么用
- 作者建议在常规CT或3-T磁共振图像上进行患者-影像配准,随后在影像导航设备上将7-T磁共振图像与常规图像融合,直至该问题解决。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ultra-high-field magnetic resonance imaging (MRI) of the brain is attractive for image guidance during neurosurgery because of its high tissue contrast and detailed vessel visualization. However, high-field MRI is prone to distortion artifacts, which may compromise image guidance. Here we investigate intra- and extracranial distortions in 7-T MRI scans. METHODS: Five patients with and 5 patients without skin-adhesive fiducials received magnetization-prepared T1-weighted 7-T MRI and standard 3-T MRI scans. The 7- and 3-T images were rigidly coregistered and compared. Intracranial distortions were evaluated qualitatively, whereas shifts at the skin surface and shifts of the center positions of skin-adhesive fiducials were measured quantitatively. Moreover, we present an illustrative case of an ultra-high-field image-guided skull base meningioma resection. RESULTS: We found excellent intracranial correspondence between 3- and 7-T MRI scans. However, the average maximum skin shift was 6.8 ± 2.0 mm in group A and 5.2 ± 0.9 mm in group B. The average maximum difference between the skin-adhesive fiducial positions was 5.6 ± 3.1 mm in group B. In our tumor resection case, the meningioma blood supply could be targeted early thanks to 7-T image guidance, which made subsequent tumor removal straightforward. CONCLUSIONS: There are no visible intracranial distortions in magnetization-prepared T1-weighted 7-T MRI cranial images. However, we found considerable extracranial shifts. These shifts render 7-T images unreliable for patient-to-image registration. We recommend performing patient-to-image registration on a routine (computed tomography scan or 3-T magnetic resonance) image and subsequently fusing the 7-T magnetic resonance image with the routine image on the image guidance machine, until this issue is resolved.
引用
- Voormolen EH, Diederen SJH, Woerdeman P, et al. Implications of Extracranial Distortion in Ultra-High-Field Magnetic Resonance Imaging for Image-Guided Cranial Neurosurgery. World Neurosurg. 2019. PMID: 30797931. doi:10.1016/j.wneu.2019.02.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。