去骨瓣减压术对颅内压的长期影响及其对颅内液体流动的可能意义
前瞻性观察研究纳入12个月内接受去骨瓣减压术的16例患者(创伤性脑损伤7例、卒中9例),植入遥测颅内压传感器并在康复期每周监测。结果显示出院后平均颅内压从7.8±2.0 mm Hg降至-1.8±3.3 mm Hg(P=0.02),体位性颅内压调节消失,颅内脉冲波幅从1.2±0.7 mm Hg降至0.4±0.3 mm Hg(P=0.05)。
要点
- 去骨瓣减压术后4周内平均颅内压降至负值(-1.8±3.3 mm Hg)。
- 术后整个随访期体位性颅内压变化消失,仰卧位与坐位颅内压无差异(P=0.67)。
- 颅内脉冲波幅从1.2±0.7 mm Hg降至0.4±0.3 mm Hg(P=0.05),可能影响颅内液体流动。
核心结论
- 神经重症监护室出院后4周内颅内压降至负值,正常体位性颅内压调节丧失,颅内脉冲波幅显著降低,这些异常可能影响去骨瓣减压术后的颅内液体流动(如脑脊液和/或类淋巴流),需进一步研究。
研究设计与样本
- 前瞻性观察研究,纳入12个月期间接受去骨瓣减压术的患者,所有患者植入遥测颅内压传感器(Neurovent-P-tel;Raumedic,Helmbrechts,德国),出院后康复期每周进行颅内压监测。
- 共纳入16例患者(创伤性脑损伤7例,卒中9例),中位年龄55岁(范围19-71岁)。
主要发现
- 从神经重症监护室出院至颅骨修补的中位时间为48天(范围16-98天),期间平均颅内压从7.8±2.0 mm Hg逐渐降至-1.8±3.3 mm Hg(P=0.02),最显著下降发生在第一个月。
- 去骨瓣减压术后整个随访期内正常体位性颅内压变化消失,即仰卧位与坐位颅内压无差异(P=0.67)。
- 颅内脉冲波幅明显降低,从初始1.2±0.7 mm Hg降至0.4±0.3 mm Hg(P=0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Decompressive craniectomy (DC) is used in cases of severe intracranial hypertension or impending intracranial herniation. DC effectively lowers intracranial pressure (ICP) but carries a risk of severe complications related to abnormal ICP and/or cerebrospinal fluid (CSF) circulation, eg, hygroma formation, hydrocephalus, and "syndrome of the trephined." OBJECTIVE: To study the long-term effect of DC on ICP, postural ICP regulation, and intracranial pulse wave amplitude (PWA). METHODS: Prospective observational study including patients undergoing DC during a 12-mo period. Telemetric ICP sensors (Neurovent-P-tel; Raumedic, Helmbrechts, Germany) were implanted in all patients. Following discharge from the neuro intensive care unit (NICU), scheduled weekly ICP monitoring sessions were performed during the rehabilitation phase. RESULTS: A total of 16 patients (traumatic brain injury: 7, stroke: 9) were included (median age: 55 yr, range: 19-71 yr). Median time from NICU discharge to cranioplasty was 48 d (range: 16-98 d) and during this period, mean ICP gradually decreased from 7.8 ± 2.0 mm Hg to -1.8 ± 3.3 mm Hg (P = .02). The most pronounced decrease occurred during the first month. Normal postural ICP change was abolished after DC for the entire follow-up period, ie, there was no difference between ICP in supine and sitting position (P = .67). PWA was markedly reduced and decreased from initially 1.2 ± 0.7 mm Hg to 0.4 ± 0.3 mm Hg (P = .05). CONCLUSION: Following NICU discharge, ICP decreases to negative values within 4 wk, normal postural ICP regulation is lost and intracranial PWA is diminished significantly. These abnormalities might have implications for intracranial fluid movements (eg, CSF and/or glymphatic flow) following DC and warrants further investigations.
引用
- Lilja-Cyron A, Andresen M, Kelsen J, et al. Long-Term Effect of Decompressive Craniectomy on Intracranial Pressure and Possible Implications for Intracranial Fluid Movements. Neurosurgery. 2020. PMID: 30768137. doi:10.1093/neuros/nyz049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。