PubMed 文献 · World Neurosurg · 2019-01-11

回顾性队列研究纳入95例功能区高级别胶质瘤手术患者,观察组49例术前行弥散张量成像(DTI)并术中荧光素钠染色(FLS),对照组46例采用常规方法。观察组切除程度83.7% vs 对照组45.7%(P<0.001),肌力下降率20.4% vs 47.8%(P=0.005),KPS评分73.5% vs 47.8%(P=0.029)。

要点

  • 观察组肿瘤切除程度显著高于对照组(83.7% vs 45.7%,P<0.001)。
  • 观察组术后肌力下降率显著低于对照组(20.4% vs 47.8%,P=0.005)。
  • 观察组KPS评分显著高于对照组(73.5% vs 47.8%,P=0.029)。

核心结论

  • 与常规胶质瘤手术相比,DTI联合FLS可促进功能区高级别胶质瘤的最大程度切除并最小化纤维束损伤,降低致残率并改善术后生活质量。

研究设计与样本

  • 回顾性队列研究,纳入2014年10月至2017年12月在郑州大学第一附属医院行功能区高级别胶质瘤手术的95例患者。
  • 观察组49例术前行DTI并术中荧光素钠染色切除肿瘤,对照组46例采用常规方法。
  • 所有患者术后72小时内行增强磁共振成像评估肿瘤切除程度,术后1个月评估肌力和KPS评分变化。

主要发现

  • 观察组肿瘤切除程度显著高于对照组(83.7% vs 45.7%,P<0.001)。
  • 观察组术后肌力下降率显著低于对照组(20.4% vs 47.8%,P=0.005)。
  • 观察组KPS评分显著高于对照组(73.5% vs 47.8%,P=0.029)。
  • 观察组中FLS识别肿瘤组织的敏感度为91.7%(44/48),特异度为90.0%(45/50)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the feasibility and clinical value of magnetic resonance diffusion tensor imaging (DTI) with fluorescein sodium staining (FLS) in the resection of high-grade glioma (HGG) in functional brain areas. METHODS: Retrospective cohort study design. The data of 95 patients who underwent surgery at the First Affiliated Hospital of Zhengzhou University for HGG in functional brain areas from October 2014 to December 2017 were investigated. In the observation group, 49 patients underwent DTI preoperatively and received FLS for the removal of tumor during the operation. In the control group, 46 patients received the routine method. All patients were subjected to enhanced magnetic resonance imaging to assess the extent of tumor resection within 72 hours after operation. The changes in muscle strength and Karnofsky Performance Status Scale (KPS) scores were evaluated 1 month after surgery. RESULTS: The extent of resection was significantly higher in the observation group than in the control group (83.7% vs. 45.7%, respectively; P < 0.001). The rate of muscle strength reduction after surgery was remarkably lower in the observation group than in the control group (20.4% vs. 47.8%, respectively; P = 0.005). KPS scores were higher in the observation group than in the control group (73.5% vs. 47.8%, respectively; P = 0.029). In the observation group, the sensitivity of FLS in identifying tumor tissue was 91.7% (44/48), with a specificity of 90.0% (45/50). CONCLUSIONS: The application of DTI with FLS can facilitate the maximum resection of HGG in functional brain areas with minimum loss of fiber tracts, reduce the disability rate, and improve quality of postoperative life compared with traditional glioma surgery.