垂体腺瘤导致视觉通路继发性白质损伤的定量评估:一项7-Tesla MRI多模态研究
本研究采用7-T DWI概率纤维束成像重建18例垂体腺瘤患者与16名健康志愿者的视束和视辐射,评估视觉通路微结构损伤并与神经眼科检查结果做相关分析。结果显示患者视束各向异性分数降低21.9%、视辐射降低17.7%,视辐射平均弥散率升高8.5%,原发视觉皮层厚度变薄,弥散指标与神经眼科检查结果显著相关。
要点
- 垂体腺瘤患者视束各向异性分数较健康对照降低21.9%(p < 0.001)。
- 患者视辐射各向异性分数降低17.7%、平均弥散率升高8.5%(均p < 0.001)。
- 视觉通路弥散指标与神经眼科检查结果显著相关,或有助于术前评估与视力恢复预后判断。
核心结论
- 基于影像的腺瘤继发性神经损伤定量结果与神经眼科检查结果高度相关。
- 超高场DWI的弥散特征或可实现视交叉受压患者视觉通路损伤的术前表征,并可能为视力可恢复性预后提供信息。
研究设计与样本
- 研究纳入18例垂体腺瘤患者和16名健康志愿者,采用7-T DWI概率纤维束成像重建视束与视辐射。
- 66.7%的患者存在视交叉受压,61.1%存在视野缺损。
- 沿纤维投射计算弥散指标,并与肿瘤体积及神经眼科检查结果做相关分析,同时评估原发视觉皮层厚度。
主要发现
- 患者视束各向异性分数较健康对照降低21.9%(p < 0.001),视辐射降低17.7%(p < 0.001)。
- 患者视辐射平均弥散率较健康对照升高8.5%(p < 0.001)。
- 垂体腺瘤患者原发视觉皮层厚度变薄。
- 视觉通路弥散指标与神经眼科检查结果显著相关。
临床怎么用
- 作者认为,超高场DWI的弥散特征或可实现视交叉受压患者视觉通路损伤的术前表征,并可能为视力可恢复性预后提供信息。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to investigate microstructural damage caused by pituitary macroadenomas by performing probabilistic tractography of the optic tracts and radiations using 7-T diffusion-weighted MRI (DWI). These imaging findings were correlated with neuro-ophthalmological results to assess the utility of ultra-high-field MRI for objective evaluation of damage to the anterior and posterior visual pathways. METHODS: Probabilistic tractography employing 7-T DWI was used to reconstruct the optic tracts and radiations in 18 patients with adenomas and in 16 healthy volunteers. Optic chiasm compression was found in 66.7% of the patients and visual defects in 61.1%. Diffusion indices were calculated along the projections and correlated with tumor volumes and results from neuro-ophthalmological examinations. Primary visual cortical thicknesses were also assessed. RESULTS: Fractional anisotropy was reduced by 21.9% in the optic tracts (p < 0.001) and 17.7% in the optic radiations (p < 0.001) in patients with adenomas. Patients showed an 8.5% increase in mean diffusivity of optic radiations compared with healthy controls (p < 0.001). Primary visual cortical thickness was reduced in adenoma patients. Diffusion indices of the visual pathway showed significant correlations with neuro-ophthalmological examination findings. CONCLUSIONS: Imaging-based quantification of secondary neuronal damage from adenomas strongly correlated with neuro-ophthalmological findings. Diffusion characteristics enabled by ultra-high-field DWI may allow preoperative characterization of visual pathway damage in patients with chiasmatic compression and may inform prognosis for vision recoverability.
引用
- Rutland JW, Padormo F, Yim CK, et al. Quantitative assessment of secondary white matter injury in the visual pathway by pituitary adenomas: a multimodal study at 7-Tesla MRI. J Neurosurg. 2019. PMID: 30660127. doi:10.3171/2018.9.JNS182022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。