蝶鞍重建使用Medpor多孔聚乙烯植入物后慢性蝶窦炎的発生
该回顾性研究分析了2008年12月至2013年1月在三级医疗中心接受内镜下经鼻经蝶窦手术(TSS)并使用Medpor进行蝶鞍重建的患者。139例中5例(3.6%)在术后8至60个月出现需手术治疗的慢性蝶窦炎,翻修术中均见植入物周围黏膜炎症和水肿,4例植入物暴露或部分挤出并取出。作者提醒术者注意植入物挤出和迟发性慢性蝶窦炎的风险。
要点
- 139例Medpor蝶鞍重建患者中5例(3.6%)在术后8至60个月出现慢性蝶窦炎并需手术处理。
- 5例均因头痛和鼻漏门诊就诊,4例有慢性鼻塞,3例反复鼻窦炎。
- 翻修术中5例均见植入物周围黏膜炎症和水肿,4例植入物暴露或部分挤出并取出。
核心结论
- 多孔聚乙烯植入物虽曾被认为用于蝶鞍重建安全有效,但术者应警惕后续植入物挤出和迟发性慢性蝶窦炎的风险。
研究设计与样本
- 回顾性研究,纳入2008年12月至2013年1月在三级医疗中心接受内镜下经鼻TSS并使用Medpor行蝶鞍重建的患者139例。
主要发现
- 139例中5例(3.6%)在术后8至60个月出现需手术治疗的慢性蝶窦炎。
- 5例均以头痛和鼻漏门诊就诊,4例有慢性鼻塞,3例反复鼻窦炎。
- 翻修术中5例均见植入物周围黏膜炎症和水肿,4例植入物暴露或部分挤出并被取出。
临床怎么用
- 作者认为,TSS后可重建蝶鞍底以预防术后并发症,但术者应了解多孔聚乙烯植入物挤出和迟发性慢性蝶窦炎的风险。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The Medpor porous polyethylene implant is reported to be safe and effective for sellar reconstruction after transsphenoidal surgery (TSS). However, we have observed several cases of delayed chronic sphenoid sinusitis related to the implant. The purpose of this study is to describe the presentation and management of implant-related sphenoid sinusitis after sellar reconstruction. METHODS: This is a retrospective study of patients who underwent endonasal TSS with Medpor sellar reconstruction between December 2008 and January 2013 at a tertiary care institution. Patient demographics, initial surgical management, sinonasal symptoms, postoperative imaging, sinusitis management, and resulting outcomes were analyzed. RESULTS: From 2008-2013, 139 patients underwent sellar reconstruction using Medpor. Five patients (3.6%) presented between 8 and 60 months after surgery with chronic sphenoid sinusitis that required surgical management. All 5 patients presented as outpatients for management of headaches and nasal drainage, 4 patients experienced chronic nasal congestion, and 3 patients noted recurrent sinusitis. At the time of revision surgery, all 5 patients were found to have mucosal inflammation and edema surrounding the implant, and 4 of the 5 had an exposed or partially extruded implant that was removed. CONCLUSIONS: Reconstruction of the sellar floor may be performed after TSS to prevent postoperative complications. Although porous polyethylene implants have previously been described as safe and effective for this purpose, surgeons should be aware of the risk of subsequent implant extrusion and chronic sphenoid sinusitis that can occur in a delayed manner.
引用
- Farrell NF, Kingdom TT, Getz AE, et al. Development of Chronic Sphenoid Sinusitis After Sellar Reconstruction with Medpor Porous Polyethylene Implant. World Neurosurg. 2018. PMID: 30579017. doi:10.1016/j.wneu.2018.12.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。