文献速递神经肿瘤

5-氨基乙酰丙酸荧光引导手术的可视化技术

Visualization technologies for 5-ALA-based fluorescence-guided surgeries.
PubMed 文献 · J Neurooncol · 2018-12-15

该综述介绍了传统宽场手术显微镜在5-氨基乙酰丙酸荧光引导手术中的局限,并系统梳理了高灵敏度探头、红光照明、光谱等技术在提升PpIX检测灵敏度与准确性方面的原理、优缺点及临床转化现状,展望了这些技术未来在胶质瘤手术中的应用前景。

要点

  • 传统宽场显微镜对低级别、非强化及深部肿瘤的荧光检测灵敏度不足。
  • 探头式可视化技术已实现低级别胶质瘤及浸润边缘PpIX表达的高灵敏检测。
  • 红光照明技术已实现最深5毫米的深部组织PpIX成像。

核心结论

  • 可视化技术的进步扩展了传统宽场手术显微镜的灵敏度和准确性,这些技术将继续改进以进一步改善胶质瘤患者5-氨基乙酰丙酸诱导荧光下的切除范围。

研究设计与样本

  • 本文为综述,描述了限制传统宽场手术显微镜灵敏度和准确性的主要因素,并调查了为解决这些挑战而开发的商用和研究原型,以及每种技术的原理、优缺点和临床转化现状。

主要发现

  • 基于探针的高灵敏度可视化技术已实现低级别胶质瘤及所有胶质瘤浸润边缘的PpIX表达检测。
  • 使用红光照明技术已实现最深5毫米的深部组织PpIX成像。
  • 光谱方法已实现对PpIX表达的更准确定量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: 5-ALA-based fluorescence-guided surgery has been shown to be a safe and effective method to improve intraoperative visualization and resection of malignant gliomas. However, it remains ineffective in guiding the resection of lower-grade, non-enhancing, and deep-seated tumors, mainly because these tumors do not produce detectable fluorescence with conventional visualization technologies, namely, wide-field (WF) surgical microscopy. METHODS: We describe some of the main factors that limit the sensitivity and accuracy of conventional WF surgical microscopy, and then provide a survey of commercial and research prototypes being developed to address these challenges, along with their principles, advantages and disadvantages, as well as the current status of clinical translation for each technology. We also provide a neurosurgical perspective on how these visualization technologies might best be implemented for guiding glioma surgeries in the future. RESULTS: Detection of PpIX expression in low-grade gliomas and at the infiltrative margins of all gliomas has been achieved with high-sensitivity probe-based visualization techniques. Deep-tissue PpIX imaging of up to 5 mm has also been achieved using red-light illumination techniques. Spectroscopic approaches have enabled more accurate quantification of PpIX expression. CONCLUSION: Advancements in visualization technologies have extended the sensitivity and accuracy of conventional WF surgical microscopy. These technologies will continue to be refined to further improve the extent of resection in glioma patients using 5-ALA-induced fluorescence.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Wei L, Roberts DW, Sanai N, et al. Visualization technologies for 5-ALA-based fluorescence-guided surgeries. J Neurooncol. 2018. PMID: 30554344. doi:10.1007/s11060-018-03077-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。