文献速递脑血管病外科神经肿瘤神经重症

支架辅助弹簧圈栓塞治疗内镜经蝶窦垂体腺瘤术后破裂的后交通动脉假性动脉瘤

Stent-Assisted Coil Embolization for a Ruptured Posterior Communicating Artery Pseudoaneurysm After Endoscopic Transsphenoidal Surgery for Pituitary Adenoma.
PubMed 文献 · World Neurosurg · 2018-12-22

本文报告一例68岁男性垂体腺瘤患者,在内镜经鼻手术后出现左侧后交通动脉假性动脉瘤并破裂出血,采用两阶段支架辅助弹簧圈栓塞治疗,术后6个月未见动脉瘤复发,10个月时改良Rankin量表评分为2分。

要点

  • 内镜经鼻手术是颅内假性动脉瘤的罕见原因。
  • 两阶段支架辅助弹簧圈栓塞使用低剖面可视化腔内支架对该假性动脉瘤有效。
  • 术后6个月未检测到动脉瘤复发,10个月时改良Rankin量表评分为2分。

核心结论

  • 使用低剖面可视化腔内支架的两阶段支架辅助弹簧圈栓塞对因内镜经蝶窦手术治疗卵泡刺激素分泌型垂体腺瘤时后交通动脉损伤后出现的后交通动脉假性动脉瘤有效。

研究设计与样本

  • 病例报告:一例68岁男性垂体腺瘤患者,在内镜经蝶窦手术后出现后交通动脉假性动脉瘤。

主要发现

  • 患者68岁,有严重成人生长激素分泌缺乏需生长激素替代治疗、继发性肾上腺皮质功能减退、甲状腺功能亢进、高血压、便秘、青光眼和高尿酸血症病史。
  • 五年前首次内镜经蝶窦垂体腺瘤手术后因再手术住院,第二次内镜经蝶窦手术中观察到后交通动脉损伤并使用止血制剂压迫止血,术后立即观察到局限性蛛网膜下腔出血。
  • 术后第7天突发意识障碍和呼吸障碍,头颅计算机断层扫描证实复发性蛛网膜下腔出血并发现继发于第三脑室阻塞的急性脑积水。
  • 全身麻醉下紧急双侧脑室引流后行脑血管造影,发现左侧后交通动脉假性动脉瘤并进行了弹簧圈栓塞。
  • 术后6周在后交通动脉放置了名为LVIS Jr.支架的低剖面可视化腔内支架,术后6个月未检测到动脉瘤复发。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intracranial pseudoaneurysm is a rare complication of endoscopic endonasal surgery. Herein, we describe 2-staged stent-assisted coil embolization for posterior communicating artery pseudoaneurysm after endoscopic endonasal surgery for pituitary adenoma. CASE DESCRIPTION: A 68-year-old man had a history of severe adult growth hormone secretion deficiency, requiring growth hormone replacement therapy; secondary adrenocortical hypofunction; hyperthyroidism; hypertension; constipation; glaucoma; and hyperuricemia. Five years ago, after initial endoscopic transsphenoidal surgery for pituitary adenoma, he was hospitalized for reoperation. Posterior communicating artery injury was observed during second endoscopic transsphenoidal surgery, and pressure hemostasis was performed using a hemostatic preparation. Immediately post surgery, a localized subarachnoid hemorrhage was observed. Sudden-onset impaired consciousness and respiratory disturbances ensued on postoperative day 7, and computed tomography of the head was performed. Recurrent subarachnoid hemorrhage was confirmed, and acute hydrocephalus secondary to third ventricular blockage was identified. Cerebral angiography was performed after urgent bilateral cerebral ventricular drainage under general anesthesia. A pseudoaneurysm was identified in the left posterior communicating artery, and coil embolization was performed. Six weeks post surgery, a low-profile visualized intraluminal stent called an LVIS Jr. stent was placed in the posterior communicating artery. Recurrence of the aneurysm was not detected 6 months post surgery. He underwent lumboperitoneal shunting for secondary normal pressure hydrocephalus after dual antiplatelet therapy discontinuation and is being followed up as an outpatient with a modified Rankin scale score of 2 ten months post surgery. CONCLUSIONS: Two-staged stent-assisted coil embolization using a low-profile visualized intraluminal stent was effective for a posterior communicating artery pseudoaneurysm occurring after posterior communicating artery injury following endoscopic transsphenoidal surgery for follicle-stimulating hormone-producing pituitary adenoma.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Morinaga Y, Nii K, Sakamoto K, et al. Stent-Assisted Coil Embolization for a Ruptured Posterior Communicating Artery Pseudoaneurysm After Endoscopic Transsphenoidal Surgery for Pituitary Adenoma. World Neurosurg. 2018. PMID: 30583130. doi:10.1016/j.wneu.2018.12.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。