文献速递脑血管病外科

直接颈动脉穿刺及动脉切开闭合装置辅助Pipeline栓塞治疗巨大海绵窦段颈内动脉瘤:神经血管内手术视频

Pipeline Embolization of Giant Cavernous Internal Carotid Artery Aneurysm with Direct Carotid Puncture and Arteriotomy Closure Device: Neuroendovascular Surgical Video.
PubMed 文献 · World Neurosurg · 2018-12-07

本文报道一例79岁女性双侧巨大海绵窦段颈内动脉瘤,右侧经Pipeline栓塞装置成功治疗,左侧因颈总动脉迂曲经股动脉入路失败。3年后因左眼疼痛及眼肌麻痹加重,在超声引导下经皮直接颈动脉穿刺,置入6F鞘,在Roadmap引导下将Marksman微导管在Navien中间导管支撑下送入左大脑中动脉,于颈内动脉床突旁及海绵窦段置入4枚Pipeline栓塞装置完全覆盖瘤颈,首次使用Mynx胶原封堵装置闭合颈动脉,患者术后无并发症,眼肌麻痹部分改善。

要点

  • 直接颈动脉穿刺可作为股动脉入路困难时的替代通路。
  • Mynx胶原封堵装置可用于颈动脉穿刺点闭合。
  • 术后患者无并发症,眼肌麻痹部分改善。

核心结论

  • 经皮直接颈动脉穿刺结合Mynx胶原封堵装置闭合,可成功完成Pipeline栓塞装置治疗巨大海绵窦段颈内动脉瘤,术后无并发症。

研究设计与样本

  • 本文为个案报道(手术视频),报道一例79岁女性双侧巨大海绵窦段颈内动脉瘤患者。

主要发现

  • 右侧巨大海绵窦段颈内动脉瘤经Pipeline栓塞装置成功治疗,左侧经股动脉入路因颈总动脉迂曲而失败。
  • 3年后患者因左眼疼痛加重及眼肌麻痹就诊,经超声引导下直接颈动脉穿刺置入6F鞘,在Roadmap引导下将Marksman微导管在Navien中间导管支撑下送入左大脑中动脉。
  • 于左侧颈内动脉床突旁及海绵窦段置入4枚Pipeline栓塞装置,完全覆盖动脉瘤颈。
  • 首次使用Mynx胶原封堵装置闭合颈动脉穿刺点,患者术后无并发症,眼肌麻痹部分改善。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Flow diversion technology has revolutionized the treatment of complex anterior circulation cerebral aneurysms. However, vessel tortuosity and atherosclerotic disease may hamper the standard transfemoral access used in these procedures. Percutaneous direct carotid puncture is a viable alternative, but adequate carotid closure must be achieved. Here, we present the first case of a giant partially thrombosed aneurysm of the cavernous internal carotid artery treated with a Pipeline embolization device (PED; ev3 Neurovascular, Irvine, California, USA) via direct carotid puncture. A 79-year-old female presented with bilateral giant cavernous internal carotid artery aneurysms. She was successfully treated with PED on the right side and failed treatment with PED on the left side using a transfemoral approach due to common carotid artery tortuosity. She was lost to follow-up but presented 3 years later with worsening left eye pain and ophthalmoplegia. Percutaneous direct carotid puncture was performed under ultrasound guidance, and a 6-French sheath was inserted. Using roadmap guidance, a Marksman microcatheter (ev3 Neurovascular) with the support of a Navien intermediate catheter (ev3 Neurovascular) was advanced into the left middle cerebral artery, and 4 PEDs were deployed within the paraclinoid and cavernous segments of the internal carotid artery to completely cover the neck of the aneurysm. Carotid closure was performed for the first time with a Mynx collagen plug device (AccessClosure, Inc., Mountain View, California, USA). The patient recovered from the procedure without any complications, and her ophthalmoplegia partially improved. Informed patient consent for the procedure and for publication was obtained (Video 1).

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Brunozzi D, Shakur SF, Alaraj A, et al. Pipeline Embolization of Giant Cavernous Internal Carotid Artery Aneurysm with Direct Carotid Puncture and Arteriotomy Closure Device: Neuroendovascular Surgical Video. World Neurosurg. 2018. PMID: 30529526. doi:10.1016/j.wneu.2018.11.230

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。