Pipeline栓塞装置与血流重定向腔内装置血流导向装置治疗颈内动脉瘤的倾向评分匹配队列研究比较
本研究通过倾向评分匹配比较Pipeline栓塞装置(PED)与血流重定向腔内装置(FRED)治疗颈内动脉瘤的效果,匹配55对动脉瘤,两组完全闭塞率均为80%(P>.99),功能结局和并发症相当,但FRED在近完全闭塞方面的优势有待进一步研究。
要点
- 匹配后两组完全闭塞率均为80%,差异无统计学意义(P>.99)。
- PED与FRED的功能结局和并发症发生率相当。
- FRED在近完全闭塞方面是否有优势需进一步研究。
核心结论
- 倾向评分匹配分析显示,PED与FRED治疗颈内动脉瘤的血管造影完全闭塞率和并发症率相当。
- FRED在近完全闭塞方面是否具有优势有待进一步研究。
研究设计与样本
- 倾向评分匹配队列研究,比较美国2个神经血管中心使用PED治疗的颈内动脉瘤与欧洲FRED研究中治疗的颈内动脉瘤。
- 匹配时控制年龄、性别、动脉瘤大小、位置、血流导向装置数量及辅助弹簧圈栓塞,最终得到55对匹配动脉瘤。
- 排除蛛网膜下腔出血情况下治疗的动脉瘤。
主要发现
- 共有221个颈内动脉瘤使用PED治疗,282个使用FRED治疗。
- FRED组中位血管造影随访时间较PED组长,但差异无统计学意义(12.2 vs 7.5个月,P=.28)。
- 完全闭塞率两组均为80%(P>.99)。
- PED与FRED的功能结局和并发症相当。
临床怎么用
- 原文未据此给出推荐。
局限性
- 局限性包括回顾性设计。
- 缺乏核心实验室对影像学结局和功能结局的独立评估。
- 原文指出结果应据此解读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Flow diversion has become an accepted endovascular treatment modality for intracranial aneurysms. Studies comparing different types of flow diverters are currently lacking. OBJECTIVE: To perform a propensity score-matched cohort study comparing the Pipeline Embolization Device (PED; Medtronic, Dublin, Ireland) and Flow Redirection Endoluminal Device (FRED; MicroVention, Aliso Viejo, California). METHODS: Aneurysms of the internal carotid artery proximal to the communicating segment treated with PED at 2 neurovascular centers in the United States were matched with aneurysms treated in the European FRED study using propensity scoring. Aneurysms treated in the setting of subarachnoid hemorrhage were excluded from matching. Occlusion rates and complications were evaluated. RESULTS: Two hundred twenty-one internal carotid artery aneurysms were treated with PED and 282 with FRED. Propensity score matching controlling for age, sex, aneurysm size, location, number of flow diverters, and adjunctive coiling resulted in 55 matched pairs. Median angiographic follow-up was nonsignificantly longer for FRED compared to PED (12.2 vs 7.5 mo, P = .28). The rate of complete occlusion did not differ between flow diverters (80% vs 80%, P > .99). Functional outcome and complications were comparable for PED and FRED. CONCLUSION: Propensity score-matched analysis of PED and FRED for internal carotid artery aneurysms revealed comparable angiographic complete occlusion and complication rates. Whether FRED has an advantage in terms of near complete aneurysm occlusion warrants further investigation. Limitations include the retrospective design and lack of an independent assessment of radiographic outcome in a core-laboratory and functional outcomes, among others, and the results should be interpreted as such.
引用
- Griessenauer CJ, Thomas AJ, Enriquez-Marulanda A, et al. Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device Flow Diverters for Internal Carotid Artery Aneurysms: A Propensity Score-Matched Cohort Study. Neurosurgery. 2019. PMID: 30541114. doi:10.1093/neuros/nyy572
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。