使用Woven EndoBridge装置治疗破裂颅内动脉瘤:两中心经验
这项回顾性观察研究纳入2014年至2017年两家学术中心连续收治的33例因破裂颅内动脉瘤导致急性蛛网膜下腔出血并接受WEB装置治疗的患者,27例存活者中26例有6个月血管造影随访,81%显示完全闭塞,24例(89%)6个月时神经功能结局良好,2例动脉瘤再治疗(占全部8%),1例致命性操作相关并发症,未见早期动脉瘤再出血。作者认为,对于解剖合适的破裂颅内动脉瘤,WEB装置治疗似乎安全且闭塞率可接受,但仍需更大规模长期研究才能给出推荐。
要点
- 33例破裂颅内动脉瘤患者在破裂后0-4天接受WEB装置治疗。
- 27例存活者中26例有6个月血管造影随访,81%显示完全闭塞。
- 27例存活者中24例(89%)6个月时神经功能结局良好,1例致命性操作相关并发症。
核心结论
- 对于解剖合适的破裂颅内动脉瘤,WEB装置治疗似乎安全且闭塞率可接受,但仍需更大规模长期研究才能给出推荐。
研究设计与样本
- 回顾性观察研究,纳入2014年(开始使用)至2017年两家学术中心连续收治的因破裂颅内动脉瘤导致急性蛛网膜下腔出血并接受WEB装置(WEB单层和单层球)治疗的全部患者,共33例。
主要发现
- 33例破裂颅内动脉瘤患者在动脉瘤破裂后0-4天接受治疗。
- 27例存活者中26例有6个月血管造影随访,其中81%显示完全闭塞。
- 27例存活者中24例(89%)在蛛网膜下腔出血后6个月神经功能结局良好。
- 2例动脉瘤再治疗(占全部8%),1例致命性操作相关并发症,未见早期动脉瘤再出血。
关键数值与推荐
- 主要结局为血管造影动脉瘤闭塞率(Beaujon Occlusion Scale Score)。
- 次要结局为早期再出血、并发症和患者结局(死亡和改良Rankin量表)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文指出仍需更大规模长期研究才能给出推荐。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Woven EndoBridge (WEB) device is a new treatment modality developed for broad-necked unruptured intracranial aneurysms (IAs) but shows potential for the treatment of ruptured IAs as well. Our aim was to describe 6-month aneurysm obliteration rates, clinical outcomes, and procedure-related complications after WEB treatment for ruptured IAs from 2 academic centers. METHODS: We conducted a retrospective observational study, including all consecutive patients treated with the WEB device (WEB single layer and single-layer sphere) for a ruptured IA causing acute subarachnoid hemorrhage between 2014 (start of use) and 2017. Primary outcome was angiographic aneurysm obliteration (Beaujon Occlusion Scale Score) rate. Secondary outcomes were early re-bleedings, complications, and patient outcome (death and modified Rankin Scale). RESULTS: A total of 33 patients with ruptured IAs were treated 0-4 days from IA rupture. Of 27 survivors, 6-month angiographic follow-up was available for 26 patients, of whom 81% showed complete occlusion. Of the 27 survivors, 24 patients (89%) had a favorable neurologic outcome at 6 months after subarachnoid hemorrhage. Two aneurysms were retreated (8% of all). There was 1 fatal procedure-related complication. No early aneurysm re-bleedings were noted. CONCLUSIONS: For anatomically suitable ruptured IAs, WEB device treatment seems to be safe and results in acceptable occlusion rates. Still, larger studies with long-term results are needed before recommendations can be made.
引用
- Raj R, Rautio R, Pekkola J, et al. Treatment of Ruptured Intracranial Aneurysms Using the Woven EndoBridge Device: A Two-Center Experience. World Neurosurg. 2018. PMID: 30576812. doi:10.1016/j.wneu.2018.12.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。