无框架机器人辅助立体脑电图在儿童难治性癫痫中的应用:准确性、实用性及技术问题
该研究前瞻性收集了14例5至18岁药物难治性癫痫患儿的机器人辅助立体脑电图(SEEG)资料,共植入164根电极,中位入点定位误差1.57毫米,中位靶点定位误差1.77毫米,记录到7次术中技术问题,2例出现并发症,所有病例的SEEG均对治疗决策有用。
要点
- 14例患儿共植入164根电极,中位入点定位误差1.57毫米,中位靶点定位误差1.77毫米。
- 记录到7次术中技术问题,2例出现并发症:1例无菌性脑膜炎,1例右侧额部血肿。
- 所有病例的SEEG均对治疗决策有用。
核心结论
- SEEG对所有儿科患者的决策都有用,机械臂是植入深部电极的准确工具,但该技术有创且并非无风险,机器人臂辅助SEEG项目初期可能出现许多问题,必须事先考虑。
研究设计与样本
- 前瞻性收集2016年4月至2018年4月间14例5至18岁(平均10岁)药物难治性癫痫患儿的SEEG指征、术中事件、术后CT与术前计划融合计算的准确性、并发症及SEEG对植入前假设的解答效用。
主要发现
- 共植入164根电极,中位入点定位误差为1.57毫米(范围1至2.25毫米),中位靶点定位误差为1.77毫米(范围1.2至2.6毫米)。
- 记录到7次术中技术问题。
- 2例患者出现并发症:1例为未检出病原体的脑膜炎,另1例为右侧额部血肿。
- 所有病例的SEEG均对治疗决策有用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Stereoelectroencephalography (SEEG) is an effective technique to help to locate and to delimit the epileptogenic area and/or to define relationships with functional cortical areas. We intend to describe the surgical technique and verify the accuracy, safety, and effectiveness of robot-assisted SEEG in a newly created SEEG program in a pediatric center. We focus on the technical difficulties encountered at the early stages of this program. METHODS: We prospectively collected SEEG indication, intraoperative events, accuracy calculated by fusion of postoperative CT with preoperative planning, complications, and usefulness of SEEG in terms of answering preimplantation hypothesis. RESULTS: Fourteen patients between the ages of 5 and 18 years old (mean 10 years) with drug-resistant epilepsy were operated on between April 2016 and April 2018. One hundred sixty-four electrodes were implanted in total. The median entry point localization error (EPLE) was 1.57 mm (1-2.25 mm) and the median target point localization error (TPLE) was 1.77 mm (1.2-2.6 mm). We recorded seven intraoperative technical issues. Two patients suffered complications: meningitis without demonstrated germ in one patient and a right frontal hematoma in the other. In all cases, the SEEG was useful for the therapeutic decision-making. CONCLUSION: SEEG has been useful for decision-making in all our pediatric patients. The robotic arm is an accurate tool for the insertion of the deep electrodes. Nevertheless, it is an invasive technique not risk-free and many problems can appear at the beginning of a robotic arm-assisted SEEG program that must be taken into account beforehand.
引用
- Candela-Cantó S, Aparicio J, López JM, et al. Frameless robot-assisted stereoelectroencephalography for refractory epilepsy in pediatric patients: accuracy, usefulness, and technical issues. Acta Neurochir (Wien). 2018. PMID: 30413938. doi:10.1007/s00701-018-3720-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。