文献速递神经肿瘤

扩散峰度成像与扩散张量成像在胶质瘤分级、预测肿瘤细胞增殖及IDH-1基因突变状态中的对比分析

Comparative analysis of the diffusion kurtosis imaging and diffusion tensor imaging in grading gliomas, predicting tumour cell proliferation and IDH-1 gene mutation status.
PubMed 文献 · J Neurooncol · 2018-11-09

研究前瞻性纳入52例病理证实的胶质瘤患者,比较扩散峰度成像(DKI)与扩散张量成像(DTI)在评估肿瘤分级、IDH-1突变状态及Ki-67增殖率中的效能。DKI参数(MK、Ka、Kr)在高别胶质瘤中显著高于低别胶质瘤,MD显著低于低别胶质瘤,Ka在预测分级、IDH-1突变及Ki-67方面表现最佳。作者认为DKI较DTI在胶质瘤综合评估中具有更大优势,Ka可能成为有前景的影像学指标。

要点

  • MK、Ka、Kr和FA在高别胶质瘤中显著高于低别胶质瘤,MD显著低于低别胶质瘤(P<0.01)。
  • MK与Ka诊断高别vs低别胶质瘤的AUC均为0.93,Ka灵敏度82%、特异度96%。
  • Ka预测IDH-1突变AUC为0.72(灵敏度74%、特异度75%),与Ki-67相关性最高(rs=0.72)。

核心结论

  • 与DTI相比,DKI在胶质瘤综合评估中具有较大优势。
  • Ka可能成为预测胶质瘤分级、肿瘤细胞增殖率和IDH-1基因突变状态的有前景的影像学指标。

研究设计与样本

  • 前瞻性纳入52例病理证实的胶质瘤患者(女性18例;中位年龄47.5岁),所有病例均行DKI检查。
  • 由DKI获得平均峰度(MK)、轴向峰度(Ka)、径向峰度(Kr)图,由DTI获得平均扩散率(MD)、各向异性分数(FA)图,每个参数手动绘制3个感兴趣区(ROI)。

主要发现

  • MK、Ka、Kr和FA在高别胶质瘤中显著高于低别胶质瘤,MD在高别胶质瘤中显著低于低别胶质瘤(P<0.01)。
  • ROC分析显示MK(特异度100%、灵敏度79%)与Ka(特异度96%、灵敏度82%)具有相同且最高的诊断价值(AUC:0.93)。
  • MK、Ka和Kr在III级胶质瘤中显著高于II级胶质瘤(P≤0.01)。
  • DKI与DTI可显著识别IDH-1突变状态(P≤0.03),其中Ka诊断价值最高(灵敏度74%、特异度75%、AUC:0.72)。
  • DKI各参数与MD均与Ki-67显著相关(P≤0.01),Ka的相关系数最高(rs=0.72)。

临床怎么用

  • 原文结论未据此给出具体临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Few studies have applied diffusion kurtosis imaging (DKI) and diffusion tensor imaging (DTI) for the comprehensive assessment of gliomas [tumour grade, isocitrate dehydrogenase-1 (IDH-1) mutation status and tumour proliferation rate (Ki-67)]. This study describes the efficacy of DKI and DTI to comprehensively evaluate gliomas, compares their results. METHODS: Fifty-two patients (18 females; median age, 47.5 years) with pathologically proved gliomas were prospectively included. All cases underwent DKI examination. DKI (mean kurtosis: MK, axial kurtosis: Ka, radial kurtosis: Kr) and DTI (mean diffusivity: MD, fractional anisotropy: FA) maps of each metric was derived. Three ROIs were manually drawn. RESULTS: MK, Ka, Kr and FA were significantly higher in HGGs than in LGGs, whereas MD was significantly lower in HGGs than in LGGs (P < 0.01). ROC analysis demonstrated that MK (specificity: 100% sensitivity: 79%) and Ka (specificity: 96% sensitivity: 82%) had the same and highest (AUC: 0.93) diagnostic value. Moreover, MK, Ka, and Kr were significantly higher in grade III than II gliomas (P ≦ 0.01). Further, DKI and DTI can significantly identify IDH-1 mutation status (P ≦ 0.03). Ka (sensitivity: 74%, specificity: 75%, AUC: 0.72) showed the highest diagnostic value. In addition, DKI metrics and MD showed significant correlations with Ki-67 (P ≦ 0.01) and Ka had the highest correlation coefficient (rs = 0.72). CONCLUSIONS: Compared with DTI, DKI has great advantages for the comprehensive assessment of gliomas. Ka might serve as a promising imaging index in predicting glioma grading, tumour cell proliferation rate and IDH-1 gene mutation status.

来源:J Neurooncol,查看原文。版权归原作者所有。

引用

  1. Zhao J, Wang YL, Li XB, et al. Comparative analysis of the diffusion kurtosis imaging and diffusion tensor imaging in grading gliomas, predicting tumour cell proliferation and IDH-1 gene mutation status. J Neurooncol. 2018. PMID: 30414095. doi:10.1007/s11060-018-03025-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。