文献速递脑血管病外科神经重症功能神经外科

颅内血管手术中皮质-皮质诱发电位监测

Monitoring Corticocortical Evoked Potentials During Intracranial Vascular Surgery.
PubMed 文献 · World Neurosurg · 2018-11-05

日本Kashiwaba神经外科医院于2016年10月至2018年1月在58例颅内血管手术中监测皮质-皮质诱发电位(CCEPs),评估其可重复性、对局部脑血流下降的动态变化及左半球语言功能监测价值。CCEPs可重复且常规监测,5例术中因血流短暂阻断出现CCEPs一过性下降,术后均无新发症状及缺血灶。

要点

  • 双侧颅内血管手术中CCEPs可重复且可常规监测,对缺血敏感。
  • 5例术中因血流短暂阻断出现CCEPs一过性下降,术后均无新发症状及缺血灶。
  • 左侧CCEPs或可作为全麻下语言功能的独特术中监测手段。

核心结论

  • 作者认为,这项先导研究显示CCEPs可在双侧颅内血管手术中常规监测,且对缺血敏感;左侧CCEPs或可作为全麻下语言功能的独特术中监测手段。

研究设计与样本

  • 作者于2016年10月至2018年1月在Kashiwaba神经外科医院前瞻性监测58例颅内血管手术的CCEPs,包括42例夹闭术、15例搭桥术(其中1例与夹闭术重叠)及2例左侧额叶和颞叶血肿清除术。

主要发现

  • 双侧血管手术中CCEPs均可重复且常规监测;无患者出现术后症状或术后MRI缺血灶;5例术中因血流短暂阻断出现CCEPs一过性下降;术中同步监测的运动诱发电位和体感诱发电位未见任何变化。

临床怎么用

  • 作者认为CCEPs可在双侧颅内血管手术中常规监测,且左侧CCEPs或可作为全麻下语言功能的独特术中监测手段。

局限性

  • 原文摘要仅称本研究为先导研究(pilot study),未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Monitoring of corticocortical evoked potentials (CCEPs) during brain tumor surgery of patients under anesthesia was recently reported to be effective in assisting in preservation of speech function. The aim of this study was to investigate whether CCEPs can be reproducibly measured between the frontal and temporal lobes during standard intracranial vascular surgery under general anesthesia; whether dynamic changes in CCEPs caused by reduced focal cerebral blood flow can be measured; and whether CCEPs can be used to monitor speech function, particularly associated with the left side of the brain. METHODS: We monitored CCEPs during 58 vascular surgeries (42 clipping procedures; 15 bypasses, 1 of which overlapped with clipping; and 2 hematoma removals from the left frontal and temporal lobe) at Kashiwaba Neurosurgical Hospital from October 2016 to January 2018. RESULTS: CCEPs could be reproducibly and routinely monitored in bilateral vascular surgeries. None of the patients experienced any postoperative symptoms or showed any ischemic lesions on postoperative magnetic resonance imaging; however, 5 patients temporarily demonstrated reduced CCEPs intraoperatively that were caused by transient obstructions of blood flow. Motor evoked potentials and somatosensory evoked potentials were simultaneously monitored intraoperatively and did not show any changes. CONCLUSIONS: The results of our pilot study show that CCEPs can be routinely monitored during bilateral intracranial vascular surgery and that they are sensitive to ischemia. CCEPs on the left side could serve as unique intraoperative monitoring of speech function under anesthesia.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Yoshimoto T, Maruichi K, Itoh Y, et al. Monitoring Corticocortical Evoked Potentials During Intracranial Vascular Surgery. World Neurosurg. 2018. PMID: 30408608. doi:10.1016/j.wneu.2018.10.179

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。