脑T1ρ成像用于胶质瘤分级及IDH1基因突变检测的初步研究
研究纳入57例胶质瘤患者,行脑MRI并定量测量T1ρ和ADC值。高级别胶质瘤实性区和瘤周水肿区T1ρ值均显著高于低级别胶质瘤,ADC无显著差异;实性区T1ρ值分级AUC为0.841。在II/III级胶质瘤中,肿瘤额叶位置和瘤周水肿区T1ρ值是IDH1突变的显著预测因子,联合诊断敏感度93.3%、特异度88.9%。
要点
- 高级别胶质瘤实性区和瘤周水肿区T1ρ值均显著高于低级别胶质瘤。
- 实性区T1ρ值分级AUC为0.841,敏感度80.6%,特异度81.0%。
- II/III级胶质瘤中,额叶位置和瘤周水肿区T1ρ值可预测IDH1突变。
核心结论
- 本研究显示T1ρ成像用于评估胶质瘤组织学分级和IDH1突变状态具有可行性。
研究设计与样本
- 本研究为初步研究,纳入57例胶质瘤患者,行脑MRI并定量测量T1ρ和表观扩散系数(ADC)值。
主要发现
- 高级别胶质瘤实性区T1ρ值显著高于低级别胶质瘤(P < 0.001),瘤周水肿区T1ρ值也显著高于低级别胶质瘤(P = 0.005)。
- 实性区和瘤周水肿区ADC值在高级别与低级别胶质瘤间均无显著差异(均P > 0.05)。
- 实性区T1ρ值分级AUC为0.841,敏感度80.6%,特异度81.0%。
- 在II/III级胶质瘤组,多因素logistic回归显示肿瘤额叶位置(OR 526.608;P = 0.045)和瘤周水肿区T1ρ值(OR 0.863;P = 0.037)均为IDH1突变的显著预测因子。
- 联合上述指标诊断IDH1突变胶质瘤的敏感度为93.3%,特异度为88.9%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The longitudinal relaxation time in the rotating frame (T1ρ) has proved to be sensitive to metabolism and useful in application to neurodegenerative diseases. However, few literature exists on its utility in gliomas. Thus, this study was conducted to explore the performance of T1ρ mapping in tumor grading and characterization of isocitrate dehydrogenase 1 (IDH1) gene mutation status of gliomas. METHODS: Fifty-seven patients with gliomas underwent brain MRI and quantitative measurements of T1ρ and apparent diffusion coefficient (ADC) were recorded. Parameters were compared between high-grade gliomas (HGG) and low-grade gliomas (LGG) and between IDH1 mutant and wildtype groups. RESULTS: HGG showed significantly higher T1ρ values in both the solid and peritumoral edema areas compared with LGG (P < 0.001 and P = 0.005, respectively), whereas no significant differences in the two areas were found for ADC (both P > 0.05). Receiver operating characteristic (ROC) curve analysis showed that T1ρ value in the solid area achieved the highest area under the ROC curve (AUC, 0.841) in grading with a sensitivity of 80.6% and a specificity of 81.0%. In the grade II/III glioma group, multivariate logistic regression showed that both tumor frontal lobe location (odds ratio [OR] 526.608; P = 0.045) and T1ρ value of the peritumoral edema area (OR 0.863; P = 0.037) were significant predictors of IDH1 mutation. Using the combination, the diagnostic sensitivity and specificity for IDH1 mutated gliomas were 93.3% and 88.9%, respectively. CONCLUSIONS: Our study shows the feasibility of applying T1ρ mapping in assessing the histologic grade and IDH1 mutation status of gliomas.
引用
- Cao M, Ding W, Han X, et al. Brain T1ρ mapping for grading and IDH1 gene mutation detection of gliomas: a preliminary study. J Neurooncol. 2018. PMID: 30414094. doi:10.1007/s11060-018-03033-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。