文献速递脑血管病外科

仅通过分析飞行时间磁共振血管造影图像检测生长中脑动脉瘤生长前的血流动力学特征:初步结果

Detection of Hemodynamic Characteristics Before Growth in Growing Cerebral Aneurysms by Analyzing Time-of-Flight Magnetic Resonance Angiography Images Alone: Preliminary Results.
PubMed 文献 · World Neurosurg · 2018-11-19

该回顾性研究用原创计算流体动力学工具分析6例生长中未破裂动脉瘤与6例稳定动脉瘤生长前TOF-MRA数据,发现生长组收缩期峰值局灶性壁面剪切应力(WSS)随时间升高,且两组WSS峰值有显著差异,提示收缩期峰值局灶性WSS升高可能是动脉瘤近期增大的危险因素。

要点

  • 生长组6例中,收缩期峰值恒定低WSS区附近局灶性WSS随时间升高。
  • 稳定组6例中3例在心动周期任何部分WSS均未升高。
  • 两组WSS峰值有显著差异,收缩期峰值局灶性WSS升高可能是近期增大危险因素。

核心结论

  • 收缩期峰值局灶性WSS升高可能是动脉瘤近期增大的危险因素。

研究设计与样本

  • 回顾性分析2013年4月至2017年3月在本研究所因动脉瘤生长而治疗的未破裂动脉瘤(生长组)及稳定5年以上未生长动脉瘤(稳定组),各6例。
  • 用原创计算流体动力学工具基于格子玻尔兹曼方法从TOF-MRA数据计算流线、WSS和振荡剪切指数三项血流动力学指标进行两组定量比较。

主要发现

  • 生长组6例中,收缩期峰值恒定低WSS区附近局灶性动脉瘤囊WSS随时间升高。
  • 稳定组6例中3例在心动周期任何部分WSS均未升高。
  • 两组WSS峰值有显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Cerebral aneurysm growth often precedes rupture. Definite contributors to aneurysm growth have not been determined even by means of recently developed commercially available computational fluid dynamics (CFD) software. We developed an original CFD tool that can analyze data from time-of-flight magnetic resonance angiography (TOF-MRA) before growth in the growing aneurysms and investigate possible factors for aneurysm growth in the near future. METHODS: We retrospectively reviewed unruptured aneurysms that were treated at our institute because of aneurysm growth (growing group) between April 2013 and March 2017. Stable aneurysms that had demonstrated no growth for more than 5 years were selected (stable group). TOF-MRA data of these aneurysms were retrospectively converted to 3-dimensional vessel geometric data; 3 hemodynamic indices including streamline, wall shear stress (WSS), and oscillatory shear index were calculated by our original CFD tool using the lattice Boltzmann method to quantitatively compare the 2 groups. RESULTS: Six growing aneurysms and 6 stable aneurysms were analyzed. Of the 6 growing aneurysms, WSS on the focal aneurysmal sac increased temporally in the vicinity of the constant low WSS area at the peak systolic phase. By contrast, WSS did not increase during any part of the cardiac cycle in 3 of the 6 stable aneurysms. The peak values of WSS were significantly different between the 2 groups. CONCLUSIONS: A focal increase in WSS in the peak systolic phase may be a risk factor for aneurysm enlargement in the near future.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Kimura H, Hayashi K, Taniguchi M, et al. Detection of Hemodynamic Characteristics Before Growth in Growing Cerebral Aneurysms by Analyzing Time-of-Flight Magnetic Resonance Angiography Images Alone: Preliminary Results. World Neurosurg. 2018. PMID: 30465954. doi:10.1016/j.wneu.2018.11.081

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。