单个开窗迷你夹在处理小型脑动脉瘤中的效用:2例技术报告
本文报告2例破裂小型动脉瘤,分别位于前交通动脉和椎动脉-小脑后下动脉,术中因瘤壁与分支血管粘连或分支血管遮挡瘤颈而难以常规夹闭。作者采用单个开窗迷你夹跨过粘连或遮挡的分支血管完成夹闭,2例均获成功且无并发症。作者认为,单个开窗迷你夹可能适用于瘤壁薄且与分支血管粘连、或瘤体被载瘤动脉遮挡的小型动脉瘤。
要点
- 开窗迷你夹可跨过与瘤壁粘连的分支血管,避免分离粘连导致的术中出血。
- 在分支血管遮挡瘤颈的狭窄术野中,开窗迷你夹可改善瘤体显露并完成夹闭。
- 单个开窗迷你夹可能适用于特定小型动脉瘤,但本文仅为2例技术报告。
核心结论
- 单个开窗迷你夹可能适用于瘤壁薄且与分支血管粘连的小型动脉瘤,或瘤体被载瘤动脉遮挡的小型动脉瘤。
研究设计与样本
- 本文为2例病例的技术报告,报告了2例破裂小型动脉瘤的手术夹闭经验。
主要发现
- 77岁女性因前交通动脉瘤破裂致蛛网膜下腔出血,经右侧翼点入路,用成角开窗迷你夹跨过同侧A2段夹闭动脉瘤,未分离粘连,无并发症。
- 60岁男性因椎动脉-小脑后下动脉动脉瘤破裂致蛛网膜下腔出血,经远外侧入路,先用开窗标准夹跨过小脑后下动脉,但该夹遮挡瘤体且在狭窄术野无法张开。
- 随后改用开窗迷你夹,在狭窄术野中瘤体显露更好,成功夹闭动脉瘤。
临床怎么用
- 作者认为,单个开窗迷你夹可能适用于瘤壁薄且与分支血管粘连的小型动脉瘤,或瘤体被载瘤动脉遮挡的小型动脉瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fenestrated miniclips were developed as an effective tool for dog-ear-shaped remnants of aneurysms. However, the special property of these clips may have other applications. Here, we report 2 cases of ruptured small aneurysm and suggest the alternative utility of a single application of a fenestrated miniclip. CASE DESCRIPTION: A 77-year-old woman was admitted to our hospital with subarachnoid hemorrhage due to an anterior communicating aneurysm. The aneurysm was treated with surgical clipping via a right pterional approach. Because dissection of tight adhesion between the aneurysm and ipsilateral A2 might cause intraoperative bleeding, the angled fenestrated miniclip was applied across the ipsilateral A2 without dissection of adhesion and obliterated the aneurysm without complications. In another case, a 60-year-old man presented with subarachnoid hemorrhage due to ruptured vertebral artery-posterior inferior cerebellar artery (PICA) aneurysm and was treated with surgical clipping via a far-lateral approach. Because aneurysm visualization was impeded by PICA even after mobilization of the PICA and vertebral artery, a fenestrated standard-clip was applied across the PICA. However, this clip impeded visualization of the aneurysm and could not be opened in the tight surgical field. In contrast, subsequent application of a fenestrated miniclip allowed better visualization of the aneurysm, even in a tight field, and resulted in successful obliteration of the aneurysm. CONCLUSION: Single application of fenestrated mini-clips may be suitable in cases of small aneurysms with thin walls adhering to branch vessels or where visualization of the aneurysm is impeded by the parent artery.
引用
- Akamatsu Y, Kashimura H, Suzuki T, et al. Utility of Single Fenestrated Miniclip in Management of Small Cerebral Aneurysm: Technical Report of 2 Cases. World Neurosurg. 2018. PMID: 30415049. doi:10.1016/j.wneu.2018.10.222
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。