文献速递神经创伤神经重症

创伤性脑损伤后最低PaO2阈值及新型脑氧合比值的临床效用

Minimal PaO2 threshold after traumatic brain injury and clinical utility of a novel brain oxygenation ratio.
PubMed 文献 · J Neurosurg · 2018-11-02

该回顾性队列研究纳入38例需监测脑组织氧分压(PbtO2)的创伤性脑损伤(TBI)患者,共收集1006个数据点,采用混合效应模型分析。结果显示维持PbtO2高于缺血阈值的最低平均PaO2为94 mmHg,仅PaO2和脑灌注压可预测PbtO2。PbtO2/PaO2比值低于0.15者占41.7%,且27.1%的测量中PbtO2正常但比值异常。作者认为TBI后早期保证足够脑氧合的最低PaO2目标应高于脑创伤基金会指南的建议值。

要点

  • 维持PbtO2高于缺血阈值的最低平均PaO2为94 mmHg。
  • 多变量分析中仅PaO2和脑灌注压可预测PbtO2。
  • PbtO2/PaO2比值低于0.15者占41.7%,27.1%测量中PbtO2正常但比值异常。

核心结论

  • 作者结果提示TBI后最初几天确保足够脑氧合的最低PaO2目标应高于脑创伤基金会指南的建议值。
  • 使用PbtO2/PaO2比值(BOx比值)可能具有临床效用,可在PbtO2正常时识别异常的氧输送机制(脑血流、弥散和脑氧代谢率)。

研究设计与样本

  • 回顾性队列研究,在学术一级创伤中心纳入38例需插入监测器测量PbtO2的TBI患者。
  • 每当进行常规动脉血气分析时同步收集PbtO2的各种决定因素,为每次血气计算PbtO2/PaO2比值并按时间绘制。
  • 所有患者按标准化临床方案管理,采用混合效应模型处理同一患者的重复测量。

主要发现

  • 共收集1006个数据点。
  • 维持PbtO2高于缺血阈值的最低平均PaO2为94 mmHg。
  • 多变量分析中仅PaO2和脑灌注压可预测PbtO2。
  • PbtO2/PaO2比值低于0.15者占全部测量的41.7%,PbtO2正常但比值异常者占27.1%。

临床怎么用

  • 作者认为TBI后最初几天确保足够脑氧合的最低PaO2目标应高于脑创伤基金会指南的建议值。
  • 作者认为PbtO2/PaO2比值(BOx比值)可能具有临床效用,可识别PbtO2正常时的异常氧输送机制。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Avoiding decreases in brain tissue oxygenation (PbtO2) after traumatic brain injury (TBI) is important. How best to adjust PbtO2 remains unclear. The authors investigated the association between partial pressure of oxygen (PaO2) and PbtO2 to determine the minimal PaO2 required to maintain PbtO2 above the hypoxic threshold (> 20 mm Hg), accounting for other determinants of PbtO2 and repeated measurements in the same patient. They also explored the clinical utility of a novel concept, the brain oxygenation ratio (BOx ratio = PbtO2/PaO2) to detect overtreatment with the fraction of inspired oxygen (FiO2). METHODS: A retrospective cohort study at an academic level 1 trauma center included 38 TBI patients who required the insertion of a monitor to measure PbtO2. Various determinants of PbtO2 were collected simultaneously whenever a routine arterial blood gas was drawn. A PbtO2/PaO2 ratio was calculated for each blood gas and plotted over time for each patient. All patients were managed according to a standardized clinical protocol. A mixed effects model was used to account for repeated measurements in the same patient. RESULTS: A total of 1006 data points were collected. The lowest mean PaO2 observed to maintain PbtO2 above the ischemic threshold was 94 mm Hg. Only PaO2 and cerebral perfusion pressure were predictive of PbtO2 in multivariate analysis. The PbtO2/PaO2 ratio was below 0.15 in 41.7% of all measures and normal PbtO2 values present despite an abnormal ratio in 27.1% of measurements. CONCLUSIONS: The authors' results suggest that the minimal PaO2 target to ensure adequate cerebral oxygenation during the first few days after TBI should be higher than that suggested in the Brain Trauma Foundation guidelines. The use of a PbtO2/PaO2 ratio (BOx ratio) may be clinically useful and identifies abnormal O2 delivery mechanisms (cerebral blood flow, diffusion, and cerebral metabolic rate of oxygen) despite normal PbtO2.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Dellazizzo L, Demers SP, Charbonney E, et al. Minimal PaO2 threshold after traumatic brain injury and clinical utility of a novel brain oxygenation ratio. J Neurosurg. 2018. PMID: 30485198. doi:10.3171/2018.5.JNS18651

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。