文献速递神经肿瘤功能神经外科

导航经颅磁刺激在钛网颅骨修补术后患者中的应用:安全且准确的操作

Navigated Transcranial Magnetic Stimulation in Patient with Cranioplasty in Situ: Safe and Accurate Procedure.
PubMed 文献 · World Neurosurg · 2018-10-06

本文报道一例59岁女性复发胶质瘤患者,既往因少突胶质细胞瘤术后感染行去骨瓣减压及钛网颅骨修补,在再次手术前接受导航经颅磁刺激(nTMS)进行运动功能区定位,未出现并发症,术中直接皮质刺激与术前nTMS结果相符,提示钛网在位时nTMS安全且准确。

要点

  • 钛网颅骨修补术后患者行nTMS运动定位未出现并发症。
  • 术中直接皮质刺激结果与术前nTMS定位相符。
  • 作者认为钛网在位时nTMS是安全且准确的操作。

核心结论

  • 本报告证实,对于钛网颅骨修补术后的患者,nTMS是一种安全且准确的操作。

研究设计与样本

  • 个案报告:一例59岁女性复发胶质瘤患者,既往诊断为世界卫生组织2级少突胶质细胞瘤,初治为放疗,5年后行手术切除,术后并伤口感染,行去骨瓣减压及伤口冲洗,随后行钛网颅骨修补。

主要发现

  • 在因复发而手术前,患者接受nTMS进行运动定位,未发现并发症。
  • 患者随后接受开颅肿瘤切除术,术中使用盐酸氨基乙酰丙酸(Gliolan),肿瘤被完全切除。
  • 术中直接皮质刺激与术前nTMS结果相符。
  • 复发肿瘤的病理诊断为间变性少突胶质细胞瘤III级,患者目前正在接受辅助化疗。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Navigated transcranial magnetic stimulation (nTMS) is a nonsurgical mapping technique used in mapping of motor and language eloquent areas within and/or surrounding brain tumors. Previous reports support this as a safe technique with minor side effects associated with minor headaches and discomfort around the stimulation area. Currently there are no published reports concerning the accuracy and safety of this procedure in patients with a titanium cranioplasty in situ. CASE PRESENTATION: A 59-year-old lady was diagnosed with a recurrent glioma in the context of increasing seizure frequency, left-sided numbness, and weakness. She was diagnosed with a World Health Organization grade 2 oligodendroglioma 10 years before her presentation, which was initially treated with radiotherapy and then surgical resection of this lesion 5 years later. The procedure was complicated with a wound infection, treated with a craniectomy and wound washout, followed by a titanium cranioplasty. Before proceeding with surgery for recurrence, nTMS was performed for motor mapping. No complications were identified. She underwent a craniotomy for tumor resection with aminolevulinic acid HCl (Gliolan), and the tumor was completely removed. Intraoperatively, the direct cortical stimulation correlated with the preoperative nTMS. The pathologic diagnosis on recurrence was an anaplastic oligodendroglioma grade III, and the patient is currently undergoing adjuvant chemotherapy. CONCLUSION: This report confirms that nTMS is a safe and accurate procedure in patients who have a titanium cranioplasty in situ.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Lavrador JP, Kandeel H, Patel S, et al. Navigated Transcranial Magnetic Stimulation in Patient with Cranioplasty in Situ: Safe and Accurate Procedure. World Neurosurg. 2018. PMID: 30296623. doi:10.1016/j.wneu.2018.09.198

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。